Rockwell Automation 1797-RPFM ControlNet Ex Modular Repeater Adapter Fiber Repeater Module User Manual

Page 28

Advertising
background image

28 ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module

Publication

1797-5.15 - June 2010

Weight

Approximately 200 g

Environmental Conditions

Operational Temperature

-20…70

o

C (-4…158

o

F)

Storage Temperature

-40…85

o

C (-40…185

o

F)

Relative Humidity

5…95% noncondensing

Shock

Operating

Tested 15 g peak acceleration, 11 (±1) ms pulse width

Nonoperating

Tested 15 g peak acceleration, 11 (±1) ms pulse width

Vibration

Tested 2 g @ 10…500 Hz per IEC 68-2-6

Agency Certification

CENELEC

II (1) 2G ib[ia] IIC T4

UL, C-UL

Class I Division 1 Groups A to D T4

Class I Zone 1 AEx ib IIC T4

FM

Class I Division 1 Groups A to D T4

Class I Zone 1 AEx ib IIC T4

INMETRO

BR-Ex ia/ib IIB/IIC T4

IECEx

Ex ib IIC T4 and Ex ib[ia] IIC T4

Certificates

CENELEC

DMT 99 ATEX E011 X

UL, C-UL

UL File Number E197983

FM

FM Certificate Number 3009806

INMETRO

05/UL-BRAE-0011X

IECEx

IECEx BVS 09.0021X

Class I Division 1 Hazardous

FM