Review the Application Conversion Log Chapter 4
"Fixed Position" decimal point display
option not supported.
<Object Name> at <Position> on
<Display Name>.
•
Numeric Input Cursor Point
•
Numeric Data Display
The object has its Decimal Point Display option set to Fixed
Position.
FactoryTalk View ME software does not support an option to
display a decimal point in a numeric value. You can achieve the
same result using an expression.
For information on a workaround, refer to page 82.
"PLC Controlled" decimal point
display option not supported.
<Object Name> at <Position> on
<Display Name>.
•
Numeric Input Cursor Point
•
Numeric Data Display
The object has its Decimal Point Display option set to PLC
Controlled.
FactoryTalk View ME software does not support an option to
display a decimal point in a numeric value. You can achieve the
same result using an expression.
For information on a workaround, refer to page 81.
"Fixed Position" decimal point input
option not supported.
<Object Name> at <Position> on
<Display Name>.
•
Numeric Input Cursor Point
•
Numeric Keypad Enable
•
Numeric Keypad object
The object has its Decimal Point Input option set to Fixed
Position.
FactoryTalk View ME software does not support an option to
input a decimal point in a numeric value. You can achieve the
same result using an expression.
For information on a workaround, refer to page 82.
"PLC Controlled" decimal point input
option not supported.
<Object Name> at <Position> on
<Display Name>.
•
Numeric Input Cursor Point
•
Numeric Keypad Enable
•
Numeric Keypad
The object has its Decimal Point Input option set to PLC
Controlled.
FactoryTalk View ME software does not support an option to
input a decimal point in a numeric value. You can achieve the
same result using an expression.
For information on a workaround, refer to page 81.
"Decimal Key Controlled" decimal
point input option not supported.
<Object Name> at <Position> on
<Display Name>.
•
Numeric Input Cursor Point
•
Numeric Keypad Enable
•
Numeric Keypad
The object has its Decimal Point Input option set to Decimal
Key Controlled.
FactoryTalk View ME software does not support an option to
input a decimal point in a numeric value. You can achieve the
same result using an expression.
For information on a workaround, refer to page 81.
Numeric Keypad converted to a
Numeric Input Enable.
<Object Name> at <Position> on
<Display Name>.
Numeric Keypad
The display contains a Numeric Keypad object.
FactoryTalk View ME software does not support a Numeric
Keypad object so converts it to a Numeric Input Enable, which
needs to be configured.
Conversion Log Messages
Message
Applies to this
PanelBuilder 1400e object
Description