Review Unsupported Features and Implement Workarounds for Migration Issues Chapter 6

9. Double-click the display

with the piloted control list
selector that requires the
Retain the Last State feature.

10. Right-click an empty area of

the screen and select
Display Settings.

11. Click the Behavior tab.

12. Click the ... button under

Macros startup to browse
for and select the Restore
Last State macro file.

13. Click the ... button under

Macros shutdown to browse
for and select the Restore
Last State macro file.

14. Click OK to accept the

changes.

15. Click X on the display and

save all changes.

You have completed the workaround for the Retain the Last State
feature. When you open a display with a piloted control list selector,
the startup display macro restores the state value from the
RetainLastState tag to the Value connection of the piloted control list
selector. When you navigate to a different display, the shutdown
macro copies the last state value of the piloted control list selector to
the RetainLastState tag.

TIP

You will need to repeat this procedure for each piloted control
list selector that requires the Retain the Last State feature. This
includes the creation of new tags and new macro files.