Master gear count 3, Motor gear count 3, Master gear count 4 – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 103: Motor gear count 4, Master gear count 5, Motor gear count 5, Master gear count 6, Motor gear count 6, Master gear count 7

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-87

270

Set

Master Gear
Count 3

UINT

2

Cnts

Master encoder counts for preset gear ratio 3. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

271

Set

Motor Gear
Count 3

INT

2

Cnts

Motor encoder counts for preset gear ratio 3. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

272

Set

Master Gear
Count 4

UINT

2

Cnts

Master encoder counts for preset gear ratio 4. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

273

Set

Motor Gear
Count 4

INT

2

Cnts

Motor encoder counts for preset gear ratio 4. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

274

Set

Master Gear
Count 5

UINT

2

Cnts

Master encoder counts for preset gear ratio 5. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

275

Set

Motor Gear
Count 5

INT

2

Cnts

Motor encoder counts for preset gear ratio 5. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

276

Set

Master Gear
Count 6

UINT

2

Cnts

Master encoder counts for preset gear ratio 6. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

277

Set

Motor Gear
Count 6

INT

2

Cnts

Motor encoder counts for preset gear ratio 6. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

278

Set

Master Gear
Count 7

UINT

2

Cnts

Master encoder counts for preset gear ratio 7. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description

Advertising