Publication 2098-RM004A-EN-P – August 2002

2-82

Programming Reference

209

Set

Flux Saturation 2

USINT

1

The motor flux saturation value at 37.5% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

210

Set

Flux Saturation 3

USINT

1

The motor flux saturation value at 50% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

211

Set

Flux Saturation 4

USINT

1

The motor flux saturation value at 62.5% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

212

Set

Flux Saturation 5

USINT

1

The motor flux saturation value at 75% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

213

Set

Flux Saturation 6

USINT

1

The motor flux saturation value at 87.5% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

214

Set

Flux Saturation 7

USINT

1

The motor flux saturation value at 100% of motor
peak current. The value is scaled so that 255
indicates no saturation, and 64 indicates 75%
saturation.
Range: 1 to 255
Default: 255

Note: Set is not allowed if the drive is enabled.

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description