Publication 2098-RM004A-EN-P – August 2002

2-94

Programming Reference

346

Set

Home Sensor
Current

UINT

2

Amps /
128

Current value used when homing to a current
setting. If the commanded current is equal to or
greater than this value, the homing sequence is
terminated or changed to searching for a marker.
Range: 1 to 32767
Default: 128

347

Set

Start Homing
Command

USINT

1

Initiates the homing procedure.
0 - No Action (default)
1 - Execute Command

348

Set

Abort Homing
Command

USINT

1

Stops execution of the homing procedure.
0 - No Action (default)
1 - Execute Command

349

Set

Pause Homing
Command

USINT

1

Pauses execution of the homing procedure.
0 - No Action (default)
1 - Continue Homing
2 - Pause Homing

350

Set

Host Index
Number

USINT

1

The index that the drive will execute if you initiate a
Start Index while Parameter 28, Host Control Mode
is set to 3 - Host Index Mode (Indexing Only). The
Host Index Number setting is not saved in
nonvolatile memory.
Range: 0 to 63
Default: 0

351

Set

Start Index
Command

USINT

1

Starts executing an index if the drive is enabled and
in an index control mode. An error may be returned if
the drive can not execute an index move or if an
index is already executing.
0 - No Action (default)
1 - Execute Command

352

Get

Index Status

WORD

2

Returns the status of an index move.
Bit 0 = Start Index Execution
Bit 1 = Start New Index Execution
Bit 2 = Index Run - In Accel or Constant Velocity
Bit 3 = In Decel
Bit 4 = In Dwell
Bit 5 = Move Adjusted by Registration
Bit 6 = End of Batch Count
Bit 7 = Negative Distance Index
Bit 8 = Registration Input Seen
Bit 9 = Not Homed - Absolute index started before
homing
Bit 10 = Aborting Index - Index is being aborted,
initiated from a digital input
Bit 11 = Blended to Index - Previous index ended
with a nonzero velocity
Bit 12 = Reversing Direction
Bit 13 = Sensor Unassigned - Registration index with
no sensor assigned
Bit 14 = Overtravel Limit - Index is being aborted,
initiated from an overtravel limit

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description