320

Set

Preset Position 4

DINT

4

Cnts

If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0

321

Set

Preset Position 4
Velocity

UDINT

4

Cnts /
Sec

The velocity used during a Preset Position 4 move.
Range: 0 to 0x7fffffff
Default: 100000

322

Set

Preset Position 4
Accel

UDINT

4

Cnts /
Sec

2

The acceleration rate used to change to a higher
velocity during a Preset Position 4 move.
Range: 0 to 0x7fffffff
Default: 100000

323

Set

Preset Position 4
Decel

UDINT

4

Cnts /
Sec

2

The deceleration rate used to change to a lower
velocity during a Preset Position 4 move.
Range: 0 to 0x7fffffff
Default: 100000

324

Set

Preset Position 5

DINT

4

Cnts

If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0

325

Set

Preset Position 5
Velocity

UDINT

4

Cnts /
Sec

The velocity used during a Preset Position 5 move.
Range: 0 to 0x7fffffff
Default: 100000

326

Set

Preset Position 5
Accel

UDINT

4

Cnts /
Sec

2

The acceleration rate used to change to a higher
velocity during a Preset Position 5 move.
Range: 0 to 0x7fffffff
Default: 100000

327

Set

Preset Position 5
Decel

UDINT

4

Cnts /
Sec

2

The deceleration rate used to change to a lower
velocity during a Preset Position 5 move.
Range: 0 to 0x7fffffff
Default: 100000

328

Set

Preset Position 6

DINT

4

Cnts

If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0

329

Set

Preset Position 6
Velocity

UDINT

4

Cnts /
Sec

The velocity used during a Preset Position 6 move.
Range: 0 to 0x7fffffff
Default: 100000

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description