Connecting dc power – Rockwell Automation 6185-A 10 Inch Monitor User Manual User Manual

Page 15

Advertising
background image

Industrial 10.4" Flat Panel Monitor

15

Publication 6185-5.0

Connecting DC Power

The 6185-A Flat Panel Monitor requires a DC power supply providing
18 to 32V DC.

To connect DC power to the monitor:

1.

Turn off the main switch or breaker.

2.

Use the ground terminal of the monitor (below the power, video and
T/S connectors) to establish a chassis-to-earth ground connection.
Secure one end of a ground strap to the ground terminal. Connect
the other end of the ground strap to a good earth ground.

The ground terminal is an M5 screw.

ATTENTION: Chassis ground must be connected for
safe operation of the monitor. The DC screw terminals on
the monitor have a chassis ground pin. However, some
DC sources may not provide a proper ground path. If you
fail to ground the monitor properly, the setup may result
in personal injury from electrical shock or damage to the
equipment.

3.

Connect the +VDC wire to the “+V” screw terminal. Connect the -
VDC wire to the “-V” screw terminal. Connect the power source
ground wire to the GND screw terminal. Tighten down the screw
terminals.

4.

Restore DC power.

Advertising