4 setting the v/hz curve jumpers (j9 through j12), Boost f (hz) v v – Rockwell Automation TD200 AC Drive V1.0, 0.3-20V RMS, 3-Ph, 63A User Manual

Page 13

Advertising
background image

Setting the Drive Jumpers

2-3

2.4

Setting the V/Hz Curve Jumpers (J9 through J12)

Jumpers J9 through J12 set the frequency break point for the V/Hz Curve . The
breakpoint is the frequency at which the output voltage reaches the maximum voltage.
Below this point the output voltage and frequency increase together. This feature is
required to allow the drive to work with motors rated at various frequencies. Figure 2.2
shows a general V/Hz curve.

Figure 2.2 – V/Hz Curve

Table 2.2 – V/Hz Curve Jumper Settings

Jumpers

Frequency at Maximum Volts

J9

J10

J11

J12

1

1

1

1

42 Hz

0

1

1

1

46 Hz

1

0

1

1

50 Hz

0

0

1

1

53 Hz

1

1

0

1

56 Hz

0

1

0

1

60 Hz

1

0

0

1

63 Hz

0

0

0

1

66 Hz

1

1

1

0

70 Hz

0

1

1

0

74 Hz

1

0

1

0

77 Hz

0

0

1

0

81 Hz

1

1

0

0

85 Hz

0

1

0

0

88 Hz

1

0

0

0

92 Hz

0

0

0

0

95 Hz

Boost

F (Hz)

V

V

max

Advertising