Ppendix, Technical specifications – Rockwell Automation TD200 AC Drive V1.0, 0.3-20V RMS, 3-Ph, 63A User Manual
Page 29

A-1
A
PPENDIX
A
Technical Specifications
Drive Dimensions
Height: 12.95 inches
Width: 6.50 inches
Depth: 4.12 inches
Weight: 7.88 pounds
Input Voltage
Nominal: +28 VDC
Operating Range: +20 to +32 VDC
Maximum Non-operating Transient: +60 V peak., 0.1 seconds
Source: battery, battery & alternator, stand-alone alternator, or DC power supply
Note: Negative voltage should not be applied to the drive.
Input Current
Nominal: +65 A DC (@ 28 VDC input and rated HP)
Output Voltage
Nominal: 0.3 to 20 V RMS, 3-phase (@ 28 VDC input)
Output Current (per phase)
Maximum Continuous: 63 A RMS, (jumper-selectable range from 30 A to 63 A)
Instantaneous Overcurrent Trip (IOC Trip):160 A peak @ 63 A jumper setting (any
phase). This value is proportional to jumper setting.
Horsepower Rating
Maximum motor size: 2 HP. Maximum continuous output current must not be
exceeded.
Efficiency
Minimum: 93% (@ 28 V input and maximum continuous output current)
Humidity and Water Splash
The drive is suitable for wash down. The drive is not submersible.