Figure 2.13 powered sensor wiring important – Rockwell Automation 1440-PK02-05M2 XM-720 Machine Monitor User Manual

Page 27

Advertising
background image

Publication GMSI10-UM001C-EN-E - June 2011

Installing the XM-720 Machine Monitor 27

Figure 2.13 Powered Sensor Wiring

IMPORTANT

A jumper from terminal 5 to 6 on the XM-120/121/122
terminal block is required for channel 1 buffered output. A
jumper from terminal 22 to 6 on XM-120/121/122
terminal block is required for channel 2 buffered output.
Refer to Setting the Buffer Range for the Transducer on
page 20.

+24V DC

Common

Signal

TYPICAL WIRING FOR ENTE K MODEL 580 VIBRATION PICKUP

TO XM-720 BACK PANEL

Cable shield not
connected at this end

17

18
19

20
21

22

23

Channel 1 Input Signal

Signal Common

Shield

+24V DC

+24V DC

Signal

Common

23

Channel 2 Input Signal

Signal Common

Shield

+24V DC