Rockwell Automation MD60 Serial Converter Module - M/N MDCOMM 232 User Manual
Page 20
![background image](/manuals/581095/20/background.png)
4-2
Serial Converter Module (MDCOMM-232)
This section is designed to help users start using VS Utilities. If you
are unsure how to complete a step, refer to the online help (select
Help > Help Topics).
Use the following procedure to configure the Serial Converter using
VS Utilities software:
Step 1.
Select Explore > Configure Communication. Select the
communications port and baud rate that you are using.
Select either checksum and accept the default time for the
time-out.
Step 2.
Select Explore > Connect > Local. A node eventually
appears under Devices.
Step 3.
In the left pane, click the + signs to expand the tree. Click
the product or Serial Converter to display parameters in
the right pane. Double-click a parameter to edit it.
Figure 4.1 – VS Utilities Screen
MD60 drive
0 - MD60 3-Phase, 230V, 1HP
1 - MDCOMM-232, RS485, RS232, DF1
VS Utilities