Installation guidelines, Figure 3.3 – e frame dimensions – Rockwell Automation SA3100 AC Power Modules User Manual
Page 23
![background image](/manuals/581221/23/background.png)
Installation Guidelines
3-5
Figure 3.3 – E Frame Dimensions
0.500
0.500
0.280
0.280
MOUNTING HOLES (4)
FRAME
REFERENCE
E-ENCLOSED
A
B
C MAX.
D
E
Y
Z
KNOCKOUTS
3-DUAL SIZE. 1-FIXED
WEIGHT
SHIPPING
510.0
(20.12)
(59.00)
1498.6
(16.71)
424.4
(18.80)
477.5
(57.00)
1447.8
(0.66)
16.8
(1.61)
40.1
92.075/104.77, 31.87,98.55
(3.625/4.125), (1.255,3.88)
186 kg
(410 lbs.)
ALL DIMENSIONS IN MILLIMETERS AND (INCHES)
ALL WEIGHTS IN KILOGRAMS AND (POUNDS)
E-OPEN
327.6
(10.66)
(360 lbs.)
163 kg
AA
126.3
(4.97)
(5.98)
151.9
1498.6
(59.00)
(20.12)
510.0
(18.80)
477.5
(0.66)
(57.00)
1447.8
16.8
(1.61)
40.1
D
A
Y
AA
C MAX.
B
E
Z
CONTROL AND SIGNAL WIRING:
FIBER-OPTIC, METER PORT, FLEX I/O,
RESOLVER FEEDBACK & DRIVE I/O,
115V/24V DC FOR PRE-CHARGE ENABLE OR
EXTERNAL 24V FOR GATE DRIVE P.S. BOARD
TE, +DC, -DC, AND PE
INPUT POWER: R(L1), S(L2), T(L3)
U(T1), V(T2), W(T3) TO MOTOR