Rockwell Automation SA3100 AC Power Modules User Manual

Page 56

Advertising
background image

A-2

SA3100 Power Modules

Programmable Carrier Frequencies

Standard Output Voltage

Seven frame sizes (B, C, D, E, F, G, H) are available. Each frame size is line
dependent and can power a motor between the following voltages:

200 - 240 VAC (line dependent)

380 - 480 VAC (line dependent)

500 - 600 VAC (line dependent)

Output Current

2.5 - 900 A @ 620 VDC

2.5 - 800 A @ 775 VDC

Output Power

2 - 116 KVA (230V)

2 - 190 KVA (380V)

2 - 208 KVA (415V)

2 - 537 KVA (460V)

2 - 671 KVA (575V)

For information on factors that could affect the power output of the Power Module
please refer to the Enclosure and Derating Guidelines of this appendix.

Output Horsepower

1 - 800 HP (Continuous)

Drive HP

Rated Carrier

Frequency

Programmable Carrier

Frequency Range

1-3

4 kHz

1-12 kHz

7.5-30

4 kHz

1-12 kHz

40-60

4 kHz

1-12 kHz

75-125

2 kHz

1-6 kHz

150-250

2 kHz

1-6 kHz

300-500

2 kHz

1-4 kHz

600-650

1.5 kHz

1-4 kHz

800

1.5 kHz

1-4 kHz

Advertising