Rockwell Automation 2097-V3xPRx-LM Kinetix 300 and Kinetix 350 Drive Systems Design Guide User Manual

Page 29

Advertising
background image

Rockwell Automation Publication GMC-RM004C-EN-P - September 2013

29

Kinetix 300 and Kinetix 350 Drive Systems

Kinetix 300/350 (200V-class) Drives/TLY-A

xxxT-H (incremental) Motor Curves

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2097-V31PR0, 2097-V32PR0, or 2097-V33PR1

and TLY-A110T-H

0

3000

5000

0.250

0.200

0.150

0.100

0.050

0

4000

1000 2000

2.21

1.77

1.33

0.88

0.44

0

6000

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2097-V31PR0, 2097-V32PR0, or 2097-V33PR1

and TLY-A110T-H (brake)

0.250

0.200

0.150

0.100

0.050

0

2.21

1.77

1.33

0.88

0.44

0

0

3000

5000

4000

1000 2000

6000

0

3000

5000

4000

1000 2000

6000

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2097-V31PR0, 2097-V32PR0, or 2097-V33PR1

and TLY-A120T-H

0.400

0.350

0.300

0.250

0.200

0.150

0.100

0.050

0

3.54

3.10

2.65

2.21

1.77

1.33

0.88

0.44

0

Intermittent curve represents

three-phase or single-phase inputs.

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2097-V31PR0, 2097-V32PR0, or 2097-V33PR1

and TLY-A120T-H (brake)

0.400

0.350

0.300

0.250

0.200

0.150

0.100

0.050

0

3.54

3.10

2.65

2.21

1.77

1.33

0.88

0.44

0

0

3000

5000

4000

1000 2000

6000

Intermittent curve represents

three-phase or single-phase inputs.

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2097-V31PR0, 2097-V32PR0, or 2097-V33PR1

and TLY-A130T-H

0.800

0.700

0.600

0.500

0.400

0.300

0.200

0.100

0

7.08

6.19

5.31

4.42

3.54

2.65

1.77

0.88

0

0

3000

5000

4000

1000 2000

6000

Intermittent curve represents

three-phase or single-phase inputs.

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2097-V31PR0, 2097-V32PR0, or 2097-V33PR1

and TLY-A130T-H (brake)

0.800

0.700

0.600

0.500

0.400

0.300

0.200

0.100

0

7.08

6.19

5.31

4.42

3.54

2.65

1.77

0.88

0

0

3000

5000

4000

1000 2000

6000

Intermittent curve represents

three-phase or single-phase inputs.

= Intermittent operating region
= Continuous operating region
= Drive operation (single-phase input)

Advertising