Rockwell Automation 2097-V3xPRx-LM Kinetix 300 and Kinetix 350 Drive Systems Design Guide User Manual

Page 71

Advertising
background image

Rockwell Automation Publication GMC-RM004C-EN-P - September 2013

71

Kinetix 300 and Kinetix 350 Drive Systems

Kinetix 300 (200V-class) Drives/LDC-Series Linear Motor Curves

200

160

120

80

40

0

45.0

36.0

27.0

18.0

9.0

0

2097-V31PR2, 2097-V32PR2, or 2097-V33PR3

and LDC-C030100-DHT

Force

(N)

Force
(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling

No Cooling

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2097-V32PR4 or 2097-V33PR5 and LDC-C030200-DHT

2097-V31PR2, 2097-V32PR2, or 2097-V33PR3 and LDC-C030200-EHT

Force

(N)

Force
(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling

No Cooling

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2097-V31PR2, 2097-V32PR2, or 2097-V33PR3

and LDC-C050100-DHT

Force

(N)

Force
(lb)

Velocity (m/s)

6

4

0

8

2

Water Cooling

Air Cooling

No Cooling

800

640

480

320

160

0

180

144

108

72.0

36.0

0

2097-V32PR4 or 2097-V33PR5 and LDC-C050200-DHT

2097-V31PR2, 2097-V32PR2, or 2097-V33PR3 and LDC-C050200-EHT

Force

(N)

Force
(lb)

Velocity (m/s)

6

4

0

8

2

Water Cooling

Air Cooling

No Cooling

1000

800

600

400

200

0

Velocity (m/s)

6

4

0

8

2

2097-V33PR6 and LDC-C050300-DHT

2097-V31PR2, 2097-V32PR2, or 2097-V33PR3 and LDC-C050300-EHT

Force

(N)

Force
(lb)

225

180

135

89.9

45.0

0

5

3

7

1

Water Cooling

Air Cooling

No Cooling

1000

800

600

400

200

0

225

180

135

90.0

45.0

0

Velocity (m/s)

1

4

3

0

6

5

2

2097-V32PR4 or 2097-V33PR5 and LDC-C075200-DHT

2097-V31PR2, 2097-V32PR2, or 2097-V33PR3 and LDC-C075200-EHT

Force

(N)

Force
(lb)

Water Cooling

Air Cooling

No Cooling

= Intermittent operating region (LDC-C

xxxxxx-DHT)

= Intermittent operating region (LDC-C

xxxxxx-EHT)

= Continuous operating region

Advertising
This manual is related to the following products: