Power Module LED Summary

E-1

A

PPENDIX

E

Power Module LED Summary

The following table summarizes the LEDs on the SA500 Power Module. Refer to the
SA500 Power Modules instruction manual (S-3018) for more information regarding the
Power Module. Refer to the SA500 Drive Configuration and Programming instruction
manual (S-3044) for more information regarding the UDC module’s dual port registers.

Name

Description

LED

PWR OK

When lit, all power supply voltages for the PMI are at acceptable
operating levels.

Related Reg/Bit

202/1202 bit 12
FLT_PS@

PMI Power Supply Fault

LED

OK

When lit, indicates the PMI has passed its internal power-up
diagnostics and the on-board watchdog timer is being updated.

LED

COMM OK

When lit, indicates messages are being received correctly from the
UDC module over the fiber-optic link.

LED

P.M. FLT

When lit, indicates one of the following fault conditions has been
detected by the PMI:

Related Reg/Bit

202/1202 bit 2
FLT_OV@

DC Bus Overvoltage

Related Reg/Bit

202/1202 bit 3
FLT_VCC@

Vcc Power Supply Undervoltage

Related Reg/Bit

202/1202 bit 0
FLT_OT@

Power Module Overtemperature

LED

EXT FLT

When lit, indicates one of the following external fault conditions has
been detected by the PMI:

Related Reg/Bit

202/1202 bit 1
FLT_IOC@

Instantaneous Overcurrent

Related Reg/Bit

202/1202 bit 10
FLT_OSP@

Overspeed

Related Reg/Bit

101/1101 bit 2
EXT_LED@

User-programmed

LED

RAIL FLT

When lit, indicates communication between a rail and the PMI has
been disrupted, or that a rail is configured but is not plugged in.

Related Reg/Bit

203/1203 bit 13
WRN_RAL@

Rail Communication Warning

LED

FDBK OK

When lit, indicates that the PMI is receiving feedback from the
resolver and no resolver feedback faults have been detected.

Related Reg/Bit

202/1202 bit 8
FLT_TBW@

Resolver Feedback Broken Wire