Troubleshoot with Indicators


The MSR241 has the following indicators:

• Module status indicator

• Network status indicator

• Output status indicators K1 and K2


Module Status Indicator
Indication

Status

Off

Device not powered

Green Device

operational

Flashing green

Device needs commissioning due to missing or incorrect
configuration, MSR241 not connected to the Safety
system MSR210

Red Unrecoverable

fault

Flashing red

Minor fault recoverable,

baud rate switches are invalid

,

MAC

ID or Baud Rate switches are changed while on line or since
reset / power-up



Network Status Indicator
Indication

Status

Off

Device not powered / Not online

Green

Link OK, On line, Connected

Flashing green

On line, Not connected

Red

Critical link failure

Flashing red

Connection timeout



Output Status Indicator K1
Indication

Status

Off K1

de-energized

Green K1

energized



Output Status Indicator K2
Indication

Status

Off K2

de-energized

Green K2

energized