Connect the relay outputs, Connect the devicenet cable – Rockwell Automation 440R MSR241 Minotaur Safety Relay User Manual
Page 2
 
MSR241 DeviceNet for Safety System MSR200
2
______________________________________________________________
Connect the MSR241 with the safety system MSR200 via 
ribbon cable 
 
The MSR241 mount to a panel or DIN rail, which must be grounded before 
installing the module. 
 
Connect the MSR241 either to the Basic module or to an output extension 
module on the right side of the MSR200 safety system via ribbon cable. 
The terminator for the EDM loop is integrated in the MSR241. 
 
 
Connect the relay outputs
 
If you want to use the relay outputs of the MSR241 connect them to your 
application. 
 
Connect the DeviceNet Cable
 
Refer to following information when connecting the DeviceNet wire to the 
MSR241. 
 
1. Connect the DeviceNet cable (drop line) to the unsealed DeviceNet
terminal connector.
2. Connect the terminal connector to the module. Use the side screws on
the terminal connector to fasten it to the module.
 
IMPORTANT 
 
Pin Number
Wire Color
Abbreviation
Description
1
Black V-
Power
return
2
Blue
CAN_L
Data line (CAN Low)
3
Clear
Shield
Between cable jacket and wire
4
White
CAN_H
Data line (CAN High)
5
Red
V+
Positive voltage (hot)
 
The bus cable must be terminated with a resistor (121 
Ω / +/- 1% / 0,25W).
The resistor is contacted with CAN_H and CAN_L.