Configuration

PVA configuration is accomplished using the DIP switches on the emitter and receiver as shown. When setting the DIP switches, use the
supplied plastic screwdriver to avoid damaging the switches or causing a short circuit.

Cover Removal

Cover Replacement

Insert a fingernail or small screwdriver into
the slot; apply gentle pressure, angling
away from the sensor lens. The cover will
remain tethered to the sensor housing.

To replace the switch cover, align one edge of the cover with the edge of the sensor
housing opening. Then press the front corners into place.

The switches determine four status operating modes:

• A/B frequency (to avoid crosstalk from multiple pairs of sensors)
• Light/dark operate
• Solid/flashing job light (depending on assembler and/or supervisor preference)
• Gate polarity

PVA Configuration DIP Switch Settings

*default settings

Switch

Emitter

Receiver

1 2 3 4

O

F

F

O

N

ON

OFF

Example Shown:
Switch #1

OFF

Switch #2

ON

Switch #3

OFF

Switch #4

ON

Figure 5. Configuration DIP switch setting posi-

tions

1

5

*ON = Frequency A
OFF = Frequency B

*ON = Frequency A
OFF = Frequency B

2

No function

ON = Light operate
*OFF = Dark operate

3

*ON = Job light steady
OFF = Job light flashes

*ON = Job light steady
OFF = Job light flashes

4

Job light control input: connect the white wire of the emitter and
receiver as follows:

Models PVA...P6
ON = Job light ON for +5 to 30V dc (27K input impedance)
*OFF = Job light ON for 0 to 2V dc/open circuit
Models PVA...N6
ON = Job light ON for +5 to 30V dc/open circuit
*OFF = Job light ON for 0 to 2V dc (10K input impedance)

5

Both emitter and receiver must be set to the same frequency in order to operate.