L-gage, Lt3 long-range time-of-flight sensor, Two discrete outputs – Banner L-GAGE LT3 Series User Manual

Page 9: Specifications, cont’d

Advertising
background image

L-GAGE

®

LT3 Long-Range Time-of-Flight Sensor –

Two Discrete Outputs

P/N 68503 rev. C

9

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Specifications, cont’d

Construction

Housing: ABS

Window: Acrylic

Quick-disconnect: ABS/polycarbonate blend

Environmental Rating

IP67, NEMA 6

Connections

2 m (6.5') or 9 m (30') shielded 7-conductor (with drain) PVC-jacketed attached cable or 8-pin Euro-style

quick-disconnect

Operating Conditions

Temperature: 0° to +50°C (+32° to +122°F)

Maximum Relative Humidity: 90% at 50°C (non-condensing)

Application Notes

• Allow 30-minute warm-up before programming or operating (see Sensor Setup, page 2).

• Retroreflective performance specifications are based on use with BRT-TVHG-8X10P high-grade target.

Results may vary with other retroreflective target materials.

Certifications

Figure 7. LT3 repeatability (diffuse mode)

1

0

1

0

2

3

Distance (m)

Resolution/Repeatability vs. Distance

4

5

2

Resolution (mm)

3

4

5

6% Black

18% Gray

90% White

Fast

Medium

Slow

-30

-20

-10

0

10

20

-40

1

0

2

3

Distance (m)

Typical Color Sensitivity

4

5

Color Sensitivity (mm)

90% White to 18% Gray

90% White to 6% Black

Figure 8. LT3 color sensitivity (typical; diffuse mode)

Figure 9. LT3 repeatability (retroreflective mode)

2

4

0

10

0

20

30

Distance (m)

Repeatability vs. Distance

40

50

6

Repeatability (mm)

8

10

12

14

16

18

20

Fast

Medium

Slow

Advertising