Banner OMNI-BEAM Series User Manual

Omni-beam, Photobus, Opbx2 power blocks for use in apc seriplex

Advertising
background image



APC Seriplex

®

networks offer unprecedented simplicity,

economy, and noise-immunity in industrial control systems
APC Seriplex networks are modular I/O systems capable of

controlling up to 510 digital I/O points on a single network
Using built-in Seriplex circuitry and assignable address codes,

OMNI-BEAM PHOTOBUS™ power blocks establish logical

relationships between the outputs of OMNI-BEAM™ sensors

and other Seriplex-compatible devices on the network
OPBX2 Series PHOTOBUS™ power blocks may be used with

all OMNI-BEAM™ Standard and E Series sensor heads

Seriplex is a registered trademark of APC.

PHOTOBUS

and

OMNI-

BEAM

are trademarks of Banner Engineering Corp.

OMNI-BEAM PHOTOBUS™ OPBX2 Series Power Blocks are APC Seri-

plex

®

compatible and may be used on Seriplex networks with any OMNI-BEAM

Standard (OSB__) or E Series (OSE_) Sensor Head.
In use, OPBX2 Series Power Block-equipped OMNI-BEAM™ sensors, the

devices to be controlled, a dc power supply, and a clock module all connect to

a common network. One wire of the network supplies dc voltage of +9 to 12

volts, one wire is common (ground), another carries data, and another carries

a synchronous, continuously-recycling clock signal. Each power block has a

built-in EEPROM that is programmed, by the user, to recognize up to two dif-

ferent address codes.
Each power block output is given access to the data line of the network when that

power block is addressed. At that time, the information on the addressed output

becomes available on the data line for control or data collection purposes. The

input(s) to any Seriplex module-equipped device(s) on the network that are to be

controlled by a specific power block output are assigned the same address code as

that power block output. The basic system, called a stand-alone system, requires

no central processor. For applications that require a more complex, central control

system, OPBX2 Series Power Blocks and APC Seriplex network technology

support the use of a host processor. Consult APC for further information.
The capacity for two address codes per power block enables both sensor head

outputs (load and alarm) of Standard OMNI-BEAM sensor heads to be used (and

addressed separately). When E Series sensor heads are used, the normally open

load output of the sensor head appears on both data outputs from the Seriplex

power block. Power block programming is easily accomplished using the SPX

Handheld Programmer (available from APC). Programming is discussed on

p. 2.
All OMNI-BEAM sensor head LED indicators and sensor head programming

DIP switches continue to function normally, as described in the sensor head

product literature, when connected to a Seriplex

®

network.

Figure 1.

OPBX2 Series Power Blocks

in a Seriplex

®

stand-alone network

AC line

12V dc

Supply

Clock

Module

Each sensor output is given a unique

address, programmed via APC

hand-held programmer.

See APC literature for more

information on network requirements,

programming, clock modules, and

power supplies.

Quick Disconnect (QD) power block

OPBX2QD requires Banner XQDC

Series mating QD cable.

APC clock module

(see Specifications)

Network:

ring, loop-back,

bus, or star.

See Specifications.

BLACK (Common)

RED (+V dc)

GREEN (Clock)

WHITE (Data)

Model OPBX2 with

built-in cable or QD

model OPBX2QD.

Model OPBX2 with

built-in cable or QD

model OPBX2QD.

BARE (Shield)

BLACK (Common)

RED (+V dc)

GREEN (Clock)

WHITE (Data)

BARE (Shield)

OPBX2QD

power block

OPBX2QD

with OSBD

sensor head

attached

APC

hand-held

progammer

OMNI-BEAM

PHOTOBUS

OPBX2 Power Blocks

for use in APC Seriplex

®

programmable control systems

Printed in USA

P/N 34940H4A

NOTE: This data sheet is concerned primarily with

operating characteristics of Banner OMNI-BEAM

OPBX2 Series Power Blocks. For information about

the APC Seriplex

®

System itself, contact APC at:

106 Business Park Drive, Jackson, MS 39213

Tel (601) 956-2800 FAX (601) 956-9777

WARNING

These photoelectric presence sensors do

NOT include the self-checking redundant circuitry necessary to

allow their use in personnel safety applications. A sensor failure

or malfunction can result in either an energized or a de-energized

sensor output condition.
Never use these products as sensing devices for personnel protec-

tion. Their use as safety devices may create an unsafe condition which could lead to

serious injury or death.
Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems

so designated, are designed to meet OSHA and ANSI machine safety standards for

point-of-operation guarding devices. No other Banner sensors or controls are designed

to meet these standards, and they must NOT be used as sensing devices for personnel

protection.

Advertising