Omni-beam sensor heads, Omni-beam sensor with attached cable – Banner OMNI-BEAM Series User Manual

Page 8

Advertising
background image

OMNI-BEAM Sensor Heads

page

8

Certifications

Supply Voltage and Current

Supplied by OMNI-BEAM power block

Output Response Time

See individual sensing heads for response times (page 2)
200 millisecond delay on power-up: outputs are non-conducting during this time.

Adjustments

OMNI-BEAM sensor heads are field-programmable for four operating parameters. A set of four
programming DIP switches is located at the base of the sensor head and is accessible with the sensor
head removed from the power block (see page 4).
Switch #1 selects the amount of sensing hysteresis
Switch #2 selects the alarm output configuration
Switch #3 selects LIGHT operate (switch #3 OFF) or DARK operate (switch #3 ON)
Switch #4 selects the STANDARD (switch #4 OFF) or FINE (switch #4 ON) scale factor for the D.A.T.A.
light signal strength indicator array

15-turn slotted brass screw Gain (sensitivity) adjustment potentiometer (clutched at both ends of travel)

Indicators

Sense and Load indicator LEDs are located on the top of the sensor head on either side of the D.A.T.A. array.

Sense LED indicates when a target has been sensed

Load LED lights whenever the load output is energized

Also, Banner’s exclusive D.A.T.A. sensor self-diagnostic system located on the top of the sensor head
warns of marginal sensing conditions usually before a sensing failure occurs (except on model OSBFAC).

Construction

Sensor heads are molded of rugged reinforced thermoplastic polyester; top view window is LEXAN

®

polycarbonate; acrylic lenses; stainless steel hardware

Environmental Rating

Meets NEMA standards 1, 2, 3, 3S, 4, 12, and 13; IEC IP66 when assembled to power block

Operating Temperature

Temperature: -40° to +70°C (-40° to +158°F)

Maximum relative humidity: 90% at 50°C (non-condensing)

OMNI-BEAM Sensor Head Specifications

OMNI-BEAM Dimensions – Sensor Head Shown Assembled to Power Block

OMNI-BEAM Sensor with Attached Cable

Transparent Cover (Gasketed)
View: D.A.T.A. Lights

Sensing Status
Output Load

Remove to Access:

Sensitivity (Gain) Adjustment
Logic Timing Adjustments

44.5 mm (1.75")

57.4 mm w/DC

(2.26")

38.1 mm w/DC

(1.50")

60.5 mm w/AC

(2.38")

79.8 mm w/AC

(3.14")

7.1 mm

(0.28")

30.0 mm

(1.18")

30.0 mm

(1.18")

7.1 mm

(0.28")

Internal Thread

(1/2-14NPSM)

External Thread

M30 X 1.5

5.6 mm (0.22")

Lens
Centerline

2 m ( 6.5' Cable)

76.2 mm w/DC Power Block
(3.00")

98.6mm w/AC Power Block
(3.88")

#10 Screw
Clearance (4)

Cross-hole design for front,
back, or side mounting

54.6 mm*

(2.15")

Hex Nut
Supplied

* 61.7 mm (2.43") for OSBCV, CVG, CVB

60.5 mm (2.38") for OSBF, FV, FVG, FVB, FX, EF, RF, FAC
59.8 mm (2.35") for OSBFP, FPG, FPB

14 mm (0.6")

Mini-style QD Connector

15 mm (0.6")

Euro-style QD Connector

OMNI-BEAM Sensor with Quick Disconnect

Mini-Style

Euro-Style

LEXAN

®

is a registered trademark of General Electric Company

Advertising