Environmental

Rating

IEC IP67; NEMA 6; (See UL section below for any ap-
plicable UL specifications)

Operating Temperature

−40 to +85 °C (Electronics); −20 to +80 °C (LCD)

Operating Humidity

95% max. relative (non-condensing)

Radiated Immunity

10 V/m, 80-2700 MHz (EN61000-6-2)

Shock and Vibration

IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz

Operating the devices at the maximum operating conditions for ex-
tended periods can shorten the life of the device.

Included with Device (DX83 Models)

The following items ship with the DX83 Ethernet Bridge.

• BWA-HW-001: Mounting Hardware Kit, containing four M5-0.8 x 25mm SS screws, four M5-0.8 x 16mm SS screws, four M5-0.8mm

SS hex nuts, and four #8-32 x 3/4" SS bolts

• BWA-EX2M: Ethernet crossover cable, M12 industrial/RJ45, 2 meter

Splitter Cables

Part No.

Model No.

Description

83265

CSRB-
M1250M125.47M125.73

Splitter cable, 5-pin Euro-style QD, No trunk male, two female
branches, black (shown).
Use to split power between two FlexPower or solar powered
devices. DO NOT use this cable to connect a FlexPower devi-
ces to a 10–30V dc powered device.

75286

CSB-M1240M1241

Splitter cable, 4-pin Euro-style QD, No trunk male, two female
branches, yellow (not shown).
Used to split power between two 10–30V dc powered devices,
such as a data radio and Gateway, or between a DX85 and
Gateway.

13805

CSRB-
M1253.28M1253.28M1253.28

Splitter cable, for dual power sources, 5-pin Euro female to 2
5-pin Euro males
Used to connect one FlexPower device (data radio, FlexPow-
ered Gateway, etc) to two power sources, such as the Flex-
Power Solar Supply and DX81P6 Battery Pack.

14642

BWA-HW-026

Splitter cable, wall wart for external power split to 5-pin Euro-
style male and 5-pin Euro female (to power a M-H at 1 Watt
while configuring it through the MHCT)

13250

BWA-DRSPLITTER

Splitter cable, DB9 Female (RS232) trunk to 5-pin Euro-style
male and female

Ethernet Cables

Part No.

Model No.

Description

77669

BWA-E2M

Ethernet cable, RSCD RJ45 440, 2M

78469

BWA-E8M

Ethernet cable, RSCD RJ45 440, 8M

78467

BWA-EX2M

Ethernet cable, crossover, RSCD RJ45CR 440, 2M

Use a crossover cable to connect the DX80 GatewayPro or DX83 Ethernet Bridge to a host system without using an Ethernet switchbox
or hub. When using a switchbox or hub, use a straight cable.

SureCross DX83 Ethernet Bridge

P/N 131934 Rev. E

www.bannerengineering.com - tel: 763-544-3164

5

Advertising