Dimensions, Glass fiber optic models – Banner D12 Series User Manual

Page 4

Advertising
background image

Dimensions

Glass Fiber Optic Models

20.2 mm

(0.79")

35.5 mm

(1.40")

Fiber-retaining Clip
(Supplied with Sensor)

7-Segment Display

Output Indicator

Power Indicator

Push Button

Pull to Relase
Bracket

5.0 mm
(0.20")

Glass Fiber Receiver Port

Glass Fiber Emitter Port

Mounting Bracket

(Included)

12.0 mm

(0.47")

30.0 mm

(1.18")

64.4 mm

(2.52")

Glass Fiber Installation.

1. Slide the sensor ends of the fiber(s) into the D12 Expert fiber ports as far as they will go.
2. Push firmly on the fiber ends to compress the o-rings (supplied with the fibers) and to align the grooves in the fiber ends with the

slot above the emitter port. Slide the retaining clip into the slot and press the clip until it snaps into the grooves.

Plastic Fiber Optic Models

20.2 mm

(0.79")

35.5 mm

(1.40")

Fiber Gripper –
Slide up to install or
release fibers

7-Segment display

Output indicator

Power indicator

Push button

Pull to release
bracket

5.0 mm
(0.20")

Plastic fiber receiver port

Plastic fiber emitter port

Mounting bracket

(included)

Small fiber adapter

12.0 mm

(0.47")

30.0 mm

(1.18")

64.4 mm

(2.52")

Plastic Fiber Installation.

1. Cut fiber ends per instructions included with the fibers. Slide the fiber gripper up (open). (For 0.010 inch or 0.020 inch diameter

fibers, insert the small fiber adaptor into the ports as far as it will go.)

2. Insert the prepared plastic fiber sensor ends gently into the ports as far as they will go.
3. Slide the fiber gripper back down to lock.