Installation, 3 hookups, 1 serial connection – Banner EZ-ARRAY USB Serial Adapter User Manual

Page 19: 2 inputs, 3 outputs, 4 synch (pink) wire, Discrete outputs, A-gage ez-array, Figure 3-5. npn hookup

Advertising
background image

P/N 126701

17

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

A-GAGE EZ-ARRAY

QuickStart Guide

Installation

wh

wh

ye

ye

gn

gn

rd

rd

gy

0-2V dc

gy

bare

bare

pk

bu

bn

pk

bu

bn

Sync

Power Supply V+

10-30V dc

Power

Power Supply V-

Sync

Power Supply V+

Power Supply V-

V Out 1

V Out 2

Out 1

Out 2

Teach

Shield

Shield

Receiver

Emitter

Load

Load

+

+

+

Figure 3-5. NPN hookup

Receiver

Emitter

wh

wh

ye

ye

gn

gn

rd

rd

gy

0-2V dc

gy

bare

bare

pk

bu

bn

pk

bu

bn

Sync

Power Supply V+

Power Supply V-

Sync

Power Supply V+

Power Supply V-

V Out 1

V Out 2

Out 1

Out 2

Teach

Shield

Shield

Load

Load

+

+

10-30V dc

Power

+

Figure 3-6. PNP hookup

Figure 3-4. Serial communication hookup

3.3 Hookups

Refer to Figures 3-4, 3-5 and 3-6 for the appropriate hookup

information.

3.3.1 Serial Connection

This connection is used only when the GUI is also used. The

receiver has a Modbus RTU-485 serial interface. A separate

5-pin Euro-style connection is provided at the opposite end of

the power cable connection, to electrically connect the serial

communication cable to an external PC or PLC. Refer to Figure

3-4; the white wire is connected to the Modbus D1/B/+ terminal

and the black wire is connected to the D0/A/— terminal.

3.3.2 Inputs

Refer to Figures 3-5 and 3-6 for standard hookup information.
Receiver gray wire: The receiver has an input that can be used

as a gate input or for remote teach. To initiate remote teach

functions, tie the wire through a switch to sensor common. To

initiate sensor scans (gate input) using this wire, see Section 5

of the full manual for more information.

3.3.3 Outputs

Refer to Figures 3-5 and 3-6 for standard hookup information

and Section 2.6 Sensor Specifications for further electrical

requirements.
Analog white and yellow wires: The receiver has two analog

outputs. Depending on receiver model, both outputs are either

voltage or current. The white wire is referenced as analog output

1; the yellow wire is referenced as analog output 2. Both analog

current and voltage will source current through an external load

to sensor common.

Discrete Outputs

The receiver has two discrete outputs; the green wire referenced

as discrete #1, and the red wire, discrete #2. Depending on

model, both outputs are either NPN or PNP. Refer to Section 2.6

Specifications for further electrical requirements.

3.3.4 Synch (Pink) Wire

The emitter and receiver are electrically synchronized via the

pink wire. The emitter and receiver pink wires must only be

electrically connected together.

Modbus

white

black

blue

D1/B/+

D0/A/–

common

brown

gray

Advertising
This manual is related to the following products: