Receiver interface, 6 troubleshooting and error codes – Banner EZ-ARRAY USB Serial Adapter User Manual

Page 24

Advertising
background image

22

P/N 126701

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

A-GAGE EZ-ARRAY

QuickStart Guide

Receiver Interface

4.6 Troubleshooting and Error Codes

If the receiver Status LED is red and the 3-digit display reads “c

followed by a number from 1 to 10, a corrective action is needed

(see below).
If the Status LED is red, but no “c” is visible on the 3-digit

display (the scan measurement mode result is displayed), the

sensor alignment is marginal. Clean the sensor windows and

perform the alignment procedure as necessary.
For all corrective actions, first verify proper supply voltages and

wiring connectivity. Disconnect and re-connect the sensor cable

connectors to verify proper connector installation.

Error
Code

Problem

Corrective Action

1

Receiver EEPROM Hard Failure

This problem is caused by a receiver failure that can not be corrected by the user.
Replace the receiver.

2

Receiver Alignment/Blanking
Configuration Error

Remove and re-apply sensor supply voltage. If the error code 2 is removed,
electrically re-align the sensor (Section 4.2). If the error code persists, contact
Banner for further problem-solving techniques.

3

Reserved for Factory

Replace the receiver.

4

Emitter or Wiring Problem

1. Verify that emitter and receiver wiring is correct (see Figures 3-5 and 3-6).
2. Check the status of the emitter Status LED.
Emitter LED OFF: Check the voltage across the emitter brown and blue wires.

If the voltage across the emitter brown and blue wire is OK, then replace the
emitter.

Emitter Status LED flashing (approx. every 2 seconds): Verify that the

emitter/receiver synch (pink) wires are correctly installed.

3. Verify that the Synch wires are correctly installed. Check the synch wire dc

voltage. If the voltage is below 1 volt or above 3 volts, then again check the synch
wire for possible mis-wiring. Unplug first the receiver and then the emitter to
determine the problem source.

5

Emitter Channel Error

The emitter has identified a nonfunctional optical channel.
Temporary fix: Perform the blanking function (Section 4.2) to ignore the problem.
Permanent fix: Replace the emitter.

6

Reserved for Factory

Replace the receiver.

7

Reserved for Factory

Replace the emitter.

8

Reserved for Factory

Replace the receiver.

9

Reserved for Factory

Replace the receiver.

10

Incompatible Scan and
Measurement Mode

Some measurement modes are incompatible with some scanning modes.
Single-Edge Scan; do not use the following measurement modes:
OD, ID, FBM, LBM, TBM, CBM, Nap Detection
Double-Edge Scan; do not use the following measurement modes:
FBM, LBM, TBM, CBM, Nap Detection

Advertising