World-beam, Qs30af adjustable-field sensor, Dynamic set – Banner WORLD-BEAM QS30 Series User Manual

Page 5

Advertising
background image

P/N 111384 rev. D

5

WORLD-BEAM

®

QS30AF Adjustable-Field Sensor

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Push Button

Remote

0.04 seconds T 0.8 seconds

Result

Sample

Target

Present

and

Absent

Conditions

Not available via push button

• Hold remote line low > 2 seconds

(until indicators flash); continue to

hold low while presenting at least 1

full application cycle

• Indicator segments

1 and 8 alternately

flash.

Return

to

RUN

Mode

• Sampling continues until the remote

line is released; then sensor returns

automatically to RUN mode.

Cutoff accepted: Sensor returns directly

to RUN mode.

Cutoff beyond sensor range: Feedback

is displayed for 2 seconds

(see page 6).*

Dynamic SET

The sensor samples the distances to both the target objects and the background

surface; the sensor places the cutoff point midway between the object and the

background. In RUN mode, objects located between the minimum range and the cutoff

are sensed; anything beyond the cutoff (e.g., other objects or background surfaces) is

ignored.
Minimum range varies, depending on the cutoff distance and reflectivity

(see Figure 11).

Sensing Distance (D)

Sensor places cutoff

switchpoint midway

Cutoff

Objects in this area are sensed

Minimum

Range

Background

Target Object

Figure 5. Dynamic SET

* Segments 7 and 8 simultaneously flashing: Indiscernible target; sensor defaults to maximum cutoff.

Segments 1 and 2 simultaneously flashing: Cutoff set is nearer than minimum cutoff; sensor defaults to minimum cutoff.

T

T T T

T

T

T

T

T

T

T

T

T

T

T

> 2 seconds

NC

NO

Advertising