Scaling Range

Scaling Range allows you to set a range from a low of 0.8 to a high of 1.2. In Run mode, this will enable matches
to occur even with slight variations in shape from the reference shape.

Tool Timeout and Absolute Positioning

Set a timeout in milliseconds that determines how long the Geometric tool will attempt to determine whether
a pattern is good or not.

Select Force to Absolute Positioning if you want to change the Geometric tool from relative positioning to
absolute.

Results

The Results field returns the following:

• Total number of shapes above the minimum acceptance level.
• Position of each shape's center. The origin (0,0) is the upper-left corner of the screen.

7.3 Vision Gray Scale Tools

Vision tools analyze an image and extract information used for judgment criteria.

7.3.1 Geometric Count Tool

The Geomtetric Count tool uses edge content to find shapes in an image. During setup, the user identifies a
section of the image containing the target shape and assigns that shape as the reference for the Geometric
Count tool. This reference shape is subsequently used to locate all similar shapes in new images by searching
inside the Search ROI. Geometric Count returns the following information:

• Number of shapes found

P/N 000000