Banner Universal Input Safety Modules User Manual

Um-fa-xa universal input safety modules, Important... read this before proceeding

Advertising
background image

For 24V ac/dc operation, solid-state or relay inputs

• Monitors a wide variety of safety and non-safety input devices:

• Optical-based safeguarding devices, such as Safety Laser Scanners
• Positive-opening safety switches used for guard interlocking
• Emergency-stop devices, such as palm buttons and rope/cable pulls
• Standard sensors for non-safety applications, such as photoelectric monitoring position

or end-of-travel.

• The safety inputs can monitor:

• +24V dc solid-state (PNP) outputs in single-channel or dual-channel hookup
• +24V dc source that is switched by hard/relay contacts in single-channel or dual-chan-

nel hookup

• Hard/relay contacts in a dual-channel hookup using terminals S11-S12 and S21-S22

• UM-FA-9A: Three normally open (N.O.) output switching channels for connection to con-

trol-reliable power interrupt circuits

• UM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.) output switching

channels for connection to control-reliable power interrupt circuits

• Automatic reset or monitored manual reset, depending on hookup
• Design complies with standards ANSI B11.19 Control Reliability, ISO 13850 (EN418), and

ISO 13849-1 (EN954-1) Category 4

• Safety Integrity Level SIL 3 per IEC 61508/IEC 62061
• Category 4 Performance level PL e per ISO 13849-1
• For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/EN 60204-1
• Plug-in terminal blocks
• 24V ac/dc operation

Models

Output Switching Channels

Safety Output Contact Rating

UM-FA-9A

3 normally open (N.O.)

6A

UM-FA-11A

2 normally open (N.O.), and 1 normally closed (N.C.)

7A

WARNING: Not a Safeguarding Device
This Banner device is considered complementary equipment that is used to augment safeguarding that
limits or eliminates an individual's exposure to a hazard without action by the individual or others. Failure
to properly safeguard hazards per a risk assessment, local regulations and relevant standards
could lead to serious injury or death.

Important... Read This Before Proceeding

The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this
product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and
maintenance instructions. Please direct any questions regarding the use or installation of this product to the factory applications depart-
ment at the telephone numbers or address found at

http://www.bannerengineering.com

.

The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and supervisors are thorough-
ly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the machinery it
controls. The user and any personnel involved with the installation and use of this product must be thoroughly familiar with all applicable
standards, some of which are listed within the specifications. Banner Engineering Corp. makes no claim regarding a specific recommen-
dation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information
for a specific application.