Banner ES-FA-6G Safety Module User Manual

Es-fa-6g 1-channel emergency stop safety module, E-stop safety module features

Advertising
background image

ES-FA-6G 1-Channel Emergency Stop Safety Module

®

24V ac/dc operation

Printed in USA

P/N 55581B9A

E-Stop Safety Module Features

Monitors one single-channel normally closed Emergency Stop switch circuit for
a contact failure or wiring fault

Three output switching channels for connection to control-reliable power
interrupt circuits

Auto reset or manual reset

One auxiliary non-safety N/C output contact for status monitoring by process
controller

Design complies with standards UL991, EN418, and EN954-1
(Safety Category 2)

For use in functional stop category 0 applications per NFPA 79
and EN418

6 amp safety output contacts

WARNING . . .

This Emergency Stop Safety Module is not a point-of-operation guarding device, as

defined by OSHA regulations. It is necessary to install point-of-operation guarding devices, such as safety
light curtains and/or hard guards, to protect personnel from hazardous machinery. Failure to install point-of-
operation guards on hazardous machinery can result in a dangerous condition which could lead to serious
injury or death.

!

p/n 55581 Rev. B