Distance settings, Sensitivity selection, Output configuration – Banner R-GAGE QT50R-RH Retroreflective High Sensitivity User Manual

Page 3

Advertising
background image

Distance Settings

* Default settings

Switch 1

Switch 2

Switch 3

Distance

EU, CN Models

US, UK Models

0

0

0

2 m (6.6 ft)

3 m (9.8 ft)

0

0

1

3 m (9.8 ft)

4 m (13.1 ft)

0

1

0

4 m (13.1 ft)

5 m (16.4 ft)

0

1

1

6 m (19.7 ft)

6 m (19.7 ft)

1*

0*

0*

8 m (26.2 ft)

8 m (26.2 ft)

1

0

1

10 m (32.8 ft)

10 m (32.8 ft)

1

1

0

12 m (39.4 ft)

12 m (39.4 ft)

1

1

1

15 m (49.2 ft)

15 m (49.2 ft)

NOTE: Highest sensitivity is achieved only if sensing distance is 8 m (26.2 ft) or less

Sensitivity Selection

* Default settings

Switch 4

Switch 5

Switch 6

Sensitivity

0*

0*

0*

8 (Highest)

0

0

1

7

0

1

0

6

0

1

1

5

1

0

0

4

1

0

1

3

1

1

0

2

1

1

1

1 (Lowest)

NOTE: Use the sensitivity selection to ignore unwanted weak reflections within the field of view, and not to
narrow the beam width. Narrow-beam R-GAGE sensor models are available.

Output Configuration

* Default settings

Switch 7

Normally Open/Normally Closed

0*

N.O.

1

N.C.

R-GAGE™ QT50RAF Sensor