Response Speed

* Default settings

Switch 8

ON

OFF

ON/OFF

0

32 ms

68 ms

100 ms

1*

258 ms

998 ms

1256 ms

Specifications

Range

The sensor is able to detect a proper object (see De-
tectable Objects) from 1 to 15 m (3.3 to 49.2 ft), de-
pending on target

Detectable Objects

Objects containing metal, water, or similar high-dielec-
tric materials

Operating Principle

Frequency modulated continuous-wave (FMCW) radar

Operating Frequency

24.00 to 24.25 GHz, ISM Band (varies slightly with
model, depending on national telecom regulations)

Supply Voltage

12 to 30V dc, less than 100 mA, exclusive of load

Supply Protection Circuitry

Protected against reverse polarity and transient over-
voltages

Delay at Power-up

Less than 2 seconds

Output Configuration

Bipolar NPN/PNP output, 150mA; DIP switch 7 selects
N.O. (default) or N.C. operation

Output Protection

Protected against short circuit conditions

Response Time

DIP-Switch 8 selects ON/OFF response time

Indicators

Power LED: Green (power ON)
Signal Strength LED: Red, flashes in proportion to
signal strength. Steady on at 4x excess gain. Only indi-
cates signal amplitude, not target distance.
Output LEDs: Yellow (output energized) / Red (config-
uration)
See

Figure 2. R-Gage Features

on page 2

Adjustments

DIP-switch-configurable sensing distance, sensitivity,
response time, and output configuration

Construction

Housing: ABS/polycarbonate
Lightpipes: Acrylic
Access Cap: Polyester

Operating Temperature

−40° to +65° C (−40° to +149° F)

Environmental Rating

IP67

Connections

Integral 5-wire 2 m (6.5 ft) cable or M12 Euro-style QD
fitting. QD models require a mating cordset

Certifications

ETSI/EN 300 440; FCC part 15; RSS-210; ANATEL
Category II; CMII Category G; ARIB STD T-73; for oth-
ers, contact Banner Engineering.

FCC ID: UE3QT50RUS—This device compiles with Part 15 of the FCC Rules. Operation is subject to the following two conditions; (1)
this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.

Este equipamento opera em caráter secundário, isto é, não tem direito à proteção
contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode cau-
sar interferência a sistemas operando em caráter primário.

R-GAGE™ QT50RAF Sensor

4

www.bannerengineering.com - tel: 763-544-3164

P/N 135460_web

Rev. E

Advertising
This manual is related to the following products: