Banner MAXI-AMP Series User Manual

Maxi-amp, Cl series, Logic-level input modules

Advertising
background image

Printed in USA

P/N 03449

F

CL Series modules are available with a solid-state relay which replaces

the electromechanical relay. This is actually two SPST solid-state

contacts. One contact will switch ac loads, and is rated at 250V ac

maximum and 3/4 amps maximum at 25 degrees C (derated to 1/2 amp

at 50 degrees C). A solid-state contact is particularly helpful when

switching inductive ac loads which can cause electrical "noise" and

contact damage when switched with a "hard" relay contact.

The other solid-state contact will switch dc loads of up to 30V dc and

up to 50 milliamps. Both solid-state outputs are electrically isolated

from the MAXI-AMP power supply. Both outputs switch within the 1

millisecond response time of the CL module circuitry. NOTE: ac loads

may take up to 1/2 cycle (8.3 milliseconds) to turn "off".

Both outputs are normally open, but may be programmed for normally

closed operation.

Except for the output configuration, the specifications for the models

listed in the table at the right are exactly the same as for the standard

CL Series models.

Solid-state Output Option

MODEL

OUTPUT

LOGIC

ON/OFF

12
timing func-
tions

105 to 130V ac, or
12 to 28V dc

210 to 250V ac, or
12 to 28V dc

CL3A
CL3B
CL5A

CL5B

105 to 130V ac, or
12 to 28V dc

210 to 250V ac, or
12 to 28V dc

SUPPLY

VOLTAGE

Banner CL Series MAXI-AMP™ modules are the perfect solution

for many sensing/control applications where economy, versatility,

dependability, and ruggedness are important. CL Series MAXI-AMPs

combine power supply, timing logic (in CL5 models) and output relay

in a single compact, cost-saving module. The integrated,

stand-alone

design saves both the expense of a separate control chassis and a sub-

stantial amount of panel space. Several models are available, for either

120V ac or 240V ac operation, and either with or without timing logic

(models are listed in table at above right). Alternatively, any model

may be powered by 12 to 28V dc.

The well-defined electrical characteristics of CL Series MAXI-AMP

modules provide a wealth of application possibilities. The input cir-

cuit accepts signals from any Banner dc sensor with an NPN (current

sinking) output; as well as from MAXI-AMP, MICRO-AMP, and

Plug Logic modules. The input is compatible with almost any sensor

or circuit which has an NPN transistor (current sinking) output. Ad-

ditionally, inputs may be generated by limit switches, contact closures,

and optical couplers. A 50mA power supply is included for powering

10 to 30V dc devices.

CL5 models offer a versatile multi-function timing logic circuit which is

programmable for twelve of the most popular and useful delay, one-shot,

and latch functions (see page 5). The MAXI-AMP offers the choice of

either single or dual timing functions in the same module.

Logic and

timing may be easily reprogrammed as control requirements change.

In order to allow accurate timing adjustments,

each CL5 model has

three time ranges to choose from. Timing adjustments are made via

rugged 15-turn potentiometers. Circuitry is included to prevent any

possibility of false output on power-up.

An auxiliary input is available on CL5 models for interrogation or

reset of the selected logic function by using an additional sensor or

input signal (see example, page 3). Page 5 describes the function of

the auxiliary input for each logic mode.

The output circuit for all CL Series modules is an SPDT 5-amp elec-

tro-mechanical relay. A solid-state relay is offered as an option to the

electromechanical relay (see information below).

Additionally, CL3 models have an NPN transistor solid-state switch.

This solid-state output may be used to take advantage of the amplifier's

fast 1-millisecond response. This output may be connected directly to

the primary or auxiliary input of other Banner logic modules, including

CL5 modules, MICRO-AMP logic modules, and Plug Logic modules.

In addition, this output can interface to other dc devices or circuits

such as counters, rate meters, or programmable controllers. Switching

capacity is 20mA at 12V dc.

The output may be programmed for either

normally open or normally closed operation.

Like all MAXI-AMPs, the CL Series modules are designed both

electrically and mechanically for solid dependability in industrial

environments.

MODEL

CL3RA
CL3RB
CL5RA

CL5RB

SPDT electro-
mechanical relay
(5 amp contact
rating)

ON/OFF

12
timing func-
tions

105 to 130V ac, or
12 to 28V dc

210 to 250V ac, or
12 to 28V dc

SUPPLY

VOLTAGE

210 to 250V ac, or
12 to 28V dc

105 to 130V ac, or
12 to 28V dc

SPST solid-

state contact for

switching AC

loads up to 250V

ac and up to 3/4

amp, plus solid-

state contact for

switching dc

loads up to 30V

dc and up to
50mA.

SPDT electro-

mechanical

relay, plus NPN

transistor solid-

state switch

OUTPUT

LOGIC

Certified

Please read Personnel Safety Warning, page

3.

MAXI-AMP

CL Series

Logic-level Input Modules

Advertising