Maxi-amp ™ cd series modules specifications – Banner MAXI-AMP Series User Manual

Page 2

Advertising
background image

MAXI-AMPCD Series Modules Specifications

Noryl

®

is a registered trademark of General Electric Co.

SUPPLY VOLTAGE: Models CD3(R)A, CD5(R)A: 105 to 130V ac,

50/60Hz (4 VA), or 12 to 28V dc* at 70mA.

Models CD3(R)B, CD5(R)B:

210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA.

*NOTE: do not connect ac power when using external dc power.
OUTPUT CONFIGURATION:

CD3A, CD3B, CD5A, CD5B: Two solid-state SPST switches, one for

ac loads of up to 250V ac and up to 3/4 amp, the other for dc loads of

up to 30V dc and up to 50mA.

CD3A and CD3B also have a logic

level current sinking NPN transistor switch at pin #9, maximum load

20mA at 12V dc max.
CD3RA and CD3RB: SPDT electromechanical relay (see specifications,

below) plus an NPN transistor solid-state logic-level dc switch (at pin

#9, maximum load 20mA at 12V dc max.).

CD5RA and CD5RB: SPDT electromechanical relay (specs below).
SPDT Electromechanical Relay Specifications:

CONTACT RATING: 250V ac max, 24V dc max, 5 amps max. (resis-

tive load), 1/10 H.P. at 240V ac. Install a transient suppressor (MOV)

across contacts that switch inductive loads.

CLOSURE TIME: 10 milliseconds max.

RELEASE TIME: 10 milliseconds max.

MAXIMUM SWITCHING SPEED: 20 operations/second

MECHANICAL LIFE: 20,000,000 operations
AMPLIFIER:

RESPONSE SPEED: Programmable for 1.5 or 15 milliseconds. NOTE:

use 15 millisecond setting for maximum sensor excess gain.
MODULATION FREQUENCY: selectable, "A" or "B".
SENSOR LEAD LENGTH: 100 feet (30 m) maximum, each sensor.

When splicing, use

separate cable for emitter and receiver, or order

sensors with extended cable length.
SENSOR HOOKUP: One SP12 Series opposed mode sensor pair per

amplifier module. Additionally, one self-contained sensor may be con-

nected at pin #9 (CD5 models) to provide a RESET or INHIBIT signal.

+15V dc power for this one additional sensor is available at module pin

#3 (40mA maximum load).
TIMERS (CD5 models only):

Timing ranges: LOW range - 10 to 150 milliseconds

MIDDLE range - 0.1 to 1.5 seconds

HIGH range - 1 to 15 seconds

Repeatability:

+/-2% of set time over all extremes of

supply voltage and temperature

ADJUSTMENTS: Miniature switches are provided for programming of

LIGHT/DARK operate, amplifier response time, modulation frequency,

normally open or normally closed output and timing function (CD5

models). 15-turn clutched potentiometer for gain (sensitivity)

and time

settings (CD5 models).

OPERATING TEMPERATURE: 0 to 50°C (+32 to 122°F).
INDICATOR LEDs: Two LEDs. A red indicator LED is "ON" when

the module output is energized. Exclusive Banner Alignment Indicating

Device (AID™) system lights another red LED indicator whenever the

receiver "sees" its own modulated light source, and pulses it at a rate

proportional to the strength of the received light signal.
CONSTRUCTION: Rugged Noryl

®

polyphenylene oxide (PPO

®

)

housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base.

Functional Schematics

NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc

device (see hookup example, page 3). Current available is 40 mA at 120V ac (240V

ac) line level; 30mA at 105V ac (210V ac) line level. Alternately, the module may be

powered by 12 to 28V dc at pins #3 (+) and #1 (-).

Do not connect ac voltage when

using external dc power.
NOTE #2: pulling pin #9 low (to common) will inhibit the timing, or reset the latch

of CD5 models (see "Description of Logic Functions", page 5).

NOTE #3: pin #9 of CD3 models may be connected directly as the input to Banner

Models CD3RA, CD3RB

Models CD5RA, CD5RB

Dimension Drawing

CL Series MAXI-AMPs or to Banner MICRO-AMP™ or Plug Logic modules (see

hookup example, page 3).

Generalized Hookup:

models with electromechanical relay output

CD3RA

CD3RB

CD5RA

CD5RB

SPDT 5A

Relay

Output

AC

Supply

8

7

6

5

4

9

10

11

1

2

3

LED +
LED -
Common
PT -

Auxiliary

(see table)

PT +

2