3) Power for External Devices (all models)

External 10 to 30V dc devices such as
self-contained sensors may be connected
between terminals #3 (+) and #1 (-) of
any CD series MAXI-AMP module.
Terminal #3 offers 40mA maximum.
This is sufficient to power most Banner
self-contained dc sensors.

As the example at the right illustrates, the

current sinking output of a self-contained

sensor powered by the MAXI-AMP may
be used as the input to the AUXILIARY
terminal of a CD5 module.

See Hookup Diagram #1 (above) for load and power connection information.

2) Logic Level NPN Output (CD3 models)

Typically, the CM5 module would be
programmed for the ONE-SHOT or
DELAYED ONE-SHOT logic func-
tion. If the SP12 pair "sees" an ac-
ceptable condition when the SP300D
senses the leading (or trailing) edge
of a product, the CD3 will inhibit a
reject pulse from occuring.

The AUXILIARY terminal (#9) of models CD3A, CD3B, CD3RA and
CD3RB modules offers a logic-level NPN (current sinking) output which
may be used as a fast-response solid-state inhibit signal to the AUXILIARY
input of MAXI-AMP CD5, CL5, CM5, or CR5 Series modules. This output

may also serve as an input to any
MICRO-AMP™, Plug Logic, or CL
Series logic module. In addition,
this output may interface to other
dc devices or circuits like counters,
rate meters, or programmable logic
controllers. Switching capacity is
20mA at 12V dc.

The example here shows the use of
SP12 Series sensors and a CD3 mod-
ule to provide inspection informa-
tion, with the SP300D functioning
as a product (GATE) sensor.

green

black

white

green

red

black

white

Gate

(Interrogate)

Data

(Inspection)

Inhibit

AC

Supply

CD3

models

8

7

6

5

4

9

10

11

1

2

3

AC

Supply

CM5

models

8

7

6

5

4

9

10

11

1

2

3

SP300D

SP12 Series Emitter

SP12 Series Receiver

blue
brown

NOTE: Black wire from

SE612

is not used

+15V dc

(#3)

GATE

(Interrogate)

CD5

models

Inhibit

White

green

blue

black

white

AC

Supply

Blue

(#1)

Brown

+15V dc @40mA

DATA

(Inspection)

SE612

8

7

6

5

4

9

10

11

1

2

3

brown

SP12 Series Emitter

SP12 Series Receiver

SP12 Series sensors are especially designed for use with CD Series modules. The basic hookup is given here. Each MAXI-AMP™ CD Series module supports
use of one pair of SP12 Series sensors. CD5 Series module models also support use of a GATE or INHIBIT sensor at pin #9 (below, this page).

1) Hookup of SP12 Series Sensors (all models)

MAXI-AMP CD Series

SP12 Sensor Hookup to CD Series MAXI-AMPModules

3

SPDT

5A

Relay

Output

AC

SUPPLY

*

LED + (white)

LED - (blue)

COMMON (black)

PT - (blue)

AUX

AC

SUPPLY

*

PT + (brown)

AC Load

DC Load

Load
Common

Models with isolated solid-state contacts

LED + (white)

LED - (blue)

COMMON (black)

PT - (blue)

AUX

CD3RA

CD3RB

CD5RA

CD5RB

8

7

6

5

4

9

10

11

1

2

3

PT + (brown)

SP12SELQD

Models with electromechanical relay contacts

*105 to 130V ac or 210 to 250V ac, 50/60Hz, depending on model. To power the MAXI-AMP™ module from a dc supply,
connect +12 to 28V dc at 70mA to terminal #3 and dc common to terminal #1. Make no connection to terminal #7 or #8.

SP12SRLQD

CD3A

CD3B

CD5A

CD5B

8

7

6

5

4

9

10

11

1

2

3

SP12SELQD

SP12SRLQD

Advertising