4

P/N 112153 rev. C

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Sensor

Output

OFF-Delay (20 ms)

Output Ends

Output

Starts

Figure 4. Output OFF-delay: Output

continues for 20 ms after sensing

stops

Sensor Setup

Output OFF-Delay

Setting an output OFF-delay extends the duration of the QL55 sensor’s ON output by

20 ms. See Figure 4. The sensor default is for no OFF-delay.
NOTE: Take precautions against potential static discharge.
To activate the output OFF-delay option:
1. Remove power from sensor.
2. Remove the four cover screws and the sensor side cover.
3. Slide DIP switch 2 (shown in Figure 5) to the ON position.
NOTE: Leave DIP switch 1 in its factory-set position.
4. Change NPN/PNP output selection, if applicable.
5. Replace the sensor side cover and screws.

Setting NPN / PNP Output

The QL55 has a selector switch for setting the output to NPN (current sinking) or PNP

(current sourcing). The sensor is pre-set with the output set to NPN. If the sensor will

be operating with an NPN output (and no output OFF-delay), the sensor housing does

not need to be opened.
NOTE: Take precautions against potential static discharge.
To set NPN or PNP output:
1. Remove power from sensor.
2. Access the red sliding NPN/PNP selector switch by removing the four cover screws

and the sensor side cover. The switch is located deep within the sensor housing;

do not confuse it with the bank of two DIP switches. The NPN/PNP selector switch

is visible below the circuit board, next to the exposed mounting screw location (see

Figure 5).

3. Carefully use a small screwdriver (preferably non-metallic) to select the NPN or

PNP switch position.

4. Replace the sensor side cover and screws before installing the sensor.
NOTE: If a cover screw is lost, contact the Banner applications group for a free

replacement (see back page for addresses).

ON

1 2

OFF-delay

Active

OFF-delay

Inactive

(default)

NPN (default)

PNP

NPN/PNP Selector

(recessed

below top board)

ON

1 2

DIP Switch 2:

Output OFF-Delay Selector

DIP Switch 1:

For factory use only;

leave in OFF position

Figure 5. Selector switches: Output OFF-

Delay and NPN/PNP output select