Ql55 series luminescence sensor, Specifications – Banner QL55 Series User Manual

Page 6

Advertising
background image

QL55 Series Luminescence Sensor

6

P/N 112153 rev. C

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Specifications

Sensing Beam

Ultraviolet high-power LED (370 nm)

Supply Voltage

10 to 30V dc, 2 V pp max ripple

80 mA max, exclusive of load

Supply Protection Circuitry

Protected against reverse polarity

Output Configuration

Discrete NPN or PNP

Analog 0 to 5.5V dc ± 10%, ripple 40 mV pp max.

Saturation Voltage: 1V max. NPN / 2V max PNP

Leakage Current: <100 µA

Output Rating

200 mA maximum load

Output Protection

NPN/PNP: Protected against reverse polarity, overload, and short circuit

(pull down/up resistance 10 kΩ)

Analog: Protected against short circuit (output resistance 2.2 kΩ)

Output Response Time

250 microseconds

Adjustments

2 push buttons (MARK and BKGD) determine switching threshold and Light/Dark operate (see page 3)

2 selector switches (see Figure 5)

• 20 ms Output OFF-delay

• NPN/PNP output

Indicators

Red Output LED

ON:

output is conducting

Green Ready/Overload LED

ON:

normal operating condition, RUN mode

Flashing 2 Hz:

setup failure due to insufficient contrast

Flashing 4 Hz:

output overload condition (verify output current ≤ 200 mA)

Construction

Housing: zinc, aluminum, and magnesium alloy

Lens: glass

Environmental Rating

IEC IP62

Connections

4-pin Euro-style (M12) QD connector. See back cover for required accessory cable options.

Operating Conditions

Temperature:

-10° to +55°C (+14° to +131°F)

Max. Relative Humidity:

85% at 50°C (non-condensing)

Data Retention

EEPROM nonvolatile memory

Scanning Range

QL55M6XD15BQ: 9 to 18 mm (0.35" to 0.71")

QL55M6XD30BQ: 20 to 40 mm (0.79" to 1.57")

QL55M6XD50BQ: 40 to 75 mm (1.57" to 2.95")

Spot Diameter

QL55M6XD15BQ: 2 mm (0.08")

QL55M6XD30BQ: 3 mm (0.12")

QL55M6XD50BQ: 4 mm (0.16")

Ambient Light Rejection

According to EN 60947-5-2

Shock Resistance

30 G; 3 shocks per axis; 11 ms duration

Vibration

0.5 mm (0.02") amplitude; 10 to 60 Hz frequency, 30 minutes for each X, Y, Z axis

Certifications

Advertising