L-gage, Laser gauging sensor, Remote programming – Banner L-GAGE LG10 Series User Manual
Page 7
Figure 4. Timing programs for remote TEACH programming
L-GAGE
™
Laser Gauging Sensor
page
7
Remote Programming
To program the sensor remotely or to disable the keypad, the Remote Programming
function may be used. Disabling the keypad prevents anyone on the production floor
from adjusting any of the programming settings. Connect the yellow wire of the
L-GAGE Laser Gauging Sensor to +5 to 30V dc, with a remote programming switch
connected between them. NOTE: The impedance of the remote teach imput is 55 k
Ω
.
Programming is accomplished by following the sequence of input pulses, following
the button-pushes and “clicks” for programming on the sensor buttons. The duration
of each pulse (corresponding to a push button “click”), and the period between
multiple pulses, are defined as: 0.04 seconds < T < 0.8 seconds.
To access each of the programming modes, pulse the remote switch a prescribed
number of times:
• 1 pulse:
Discrete TEACH Mode
• 2 pulses:
Analog TEACH Mode
• 3 pulses:
Dual Discrete/Analog TEACH Mode
• 4 pulses:
Disables (locks out) or enables the keypad for security
Teach First
Discrete Limit
Discrete
Limits Only
Teach Second
Discrete Limit
Teach First
Analog Limit
Teach First Limits
Teach Second Limits
Push Button Lockout
Analog
Limits Only
Teach Second
Analog Limit
Analog & Digital
Together
Push Button
Lockout
T
> 0.8 sec
> 0.8 sec
T
T
T
T
T
T
T
T
T
T
T
T
T
T
> 0.8 sec
T
T
T
T
0.04 sec < T < 0.8 sec