Figure 4. Timing programs for remote TEACH programming

L-GAGE

Laser Gauging Sensor

page

7

Remote Programming

To program the sensor remotely or to disable the keypad, the Remote Programming
function may be used. Disabling the keypad prevents anyone on the production floor
from adjusting any of the programming settings. Connect the yellow wire of the
L-GAGE Laser Gauging Sensor to +5 to 30V dc, with a remote programming switch
connected between them. NOTE: The impedance of the remote teach imput is 55 k

.

Programming is accomplished by following the sequence of input pulses, following
the button-pushes and “clicks” for programming on the sensor buttons. The duration
of each pulse (corresponding to a push button “click”), and the period between
multiple pulses, are defined as: 0.04 seconds < T < 0.8 seconds.

To access each of the programming modes, pulse the remote switch a prescribed
number of times:

• 1 pulse:

Discrete TEACH Mode

• 2 pulses:

Analog TEACH Mode

• 3 pulses:

Dual Discrete/Analog TEACH Mode

• 4 pulses:

Disables (locks out) or enables the keypad for security

Teach First

Discrete Limit

Discrete

Limits Only

Teach Second

Discrete Limit

Teach First

Analog Limit

Teach First Limits

Teach Second Limits

Push Button Lockout

Analog

Limits Only

Teach Second

Analog Limit

Analog & Digital

Together

Push Button

Lockout

T

> 0.8 sec

> 0.8 sec

T

T

T

T

T

T

T

T

T

T

T

T

T

T

> 0.8 sec

T

T

T

T

0.04 sec < T < 0.8 sec