Banner VALU-BEAM SMI912 Series—Intrinsically Safe User Manual

Page 4

Advertising
background image

Sensors include Banner's exclusive Alignment Indicat-
ing Device (AID™) system, which lights a top-mounted
red indicator LED whenever the sensor “sees” its
modulated light source, and pulses the LED at a rate
proportional to the received light signal strength.

Construction

Housing: reinforced PBT, totally encapsulated
Lenses: molded acrylic
Hardware: stainless steel

Connections

Supplied with integral 3-pin Mini-style QD fitting; re-
quires cordset model MBCC (see Accessories), pur-
chased separately.

Repeatability

Opposed mode: 1.0 millisecond
All other modes: 1.3 milliseconds
Repeatability is independent of signal strength.

Environmental Ratings

Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12, and 13,
IEC IP66

Operating Conditions

Temperature: –20 to +70 °C (–4 to +158 °F)
Max. Relative Humidity: 90% @ 50 °C (non-condens-
ing)

Certifications

Application Note

Special Conditions for Safe Use: Parts of the enclosure are non-
conducting and may generate an ignition-capable level of ESD.
Cleaning of the equipment shall be done only with a damp cloth.

Design Standards

ATEX (European)

EN 60079-0, EN 60079-11, EN 60079-26

Canadian

CAN/CSA C22.2 No. 0-M91, No. 142-M1987, No.157-92, No. 1010.1, E60079-0, E60079-11

United States

FM Class 3600, 3610, and 3810, ANSI/ISA 61010-1 (82.02.01), ANSI/ISA 60079-0, 60079-11, and
60079-26.

Approvals

ATEX (European)

II 2 G Ex ib IIC T5 Ta = -40°C to 70°C - 03396; Entity FM12ATEX094X
Entity Parameters: VMax = 30 V, IMax = 350 mA, Ci = 0 μF, Li = 0 mH.

Canadian

SMI91(a)
Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40°C to 70°C
a = 2LVQD, 2DQD, 2DSRQD, 2FQD, 2CVQD, 2LVAGQD or 2FPQD.

SMI91(b)
Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40°C to 70°C
Intrinsically safe for Class I, Zone 1 AEx ib Group IIC T5 Ta = -40°C to 70°C; - 03396, Entity
Entity Parameters: VMax = 30 V, IMax = 350 mA, Ci = 0 μF, Li = 0 mH.
b = 1RQD, RSRQD, RFQD, EQD, ESRQD or EFQD.

United States

SMI91(a)
Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40°C to 70°C
Suitable for Class II and III, Division 2, Groups F and G*, T5 Ta = -40°C to 70°C
a = 2LVQD, 2DQD, 2DSRQD, 2FQD, 2CVQD, 2LVAGQD or 2FPQD.

SMI91(b)
Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40°C to 70°C
Suitable for Class II and III, Division 2, Groups F and G*, T5 Ta = -40°C to 70°C
Intrinsically safe for Class I, Zone 1 AEx ib Group IIC T5 Ta = -40°C to 70°C - 03396; Entity
Entity Parameters: VMax = 30 V, IMax = 350 mA, Ci = 0 μF, Li = 0 mH.
b = 1RQD, RSRQD, RFQD, EQD, ESRQD or EFQD.

VALU-BEAM SMI912 Series

4

www.bannerengineering.com - tel: 763-544-3164

P/N 03396 Rev. K

Advertising
This manual is related to the following products: