Accessories, Wire hookup 2-wire hookup – Banner VALU-BEAM SMI912 Series—Intrinsically Safe User Manual

Page 8

Advertising
background image

OUT

IN

OUT

BROWN

BLACK

INPUT

+

-

OUT

BROWN

BLACK

BUSBAR

+

-

3

2

3

+

I.S.

+

-

I.S.

+

-

-

+

+

+

Operating Voltage

18-30V dc

25 mA dc

3-Wire Hookup

2-Wire Hookup

Barriers not required for Div. 2
30V dc (reference NOTE #5 for FM & CSA on page 3)

2

3

4

4

2

3

Safe area

Hazardous area

15 mA
max.

L
O
A
D

IN

V

SMI900
Series Sensor

Bottom view
(colors shown are for mating
cordset MBCC-312)

Blue

Busbar

G

Earth ground
(less than 1 ohm)

Connection to control room
equipment should not use or
generate more than 250V

Note: Emitters have no output connection (no connection to black wire)

Safe area

Hazardous area

Barriers not required for Div 2
30V dc max. (Reference Note #5 for FM & CSA)

≤ 10 mA (OFF state)
≥ 20 mA (ON state)

Sensor

Barrier

IN

V

SMI900
Series Sensor

Bottom view
(colors shown are for mating
cordset MBCC-312)

Blue

Input

Operating voltage

18–30V dc

25 mA dc

Earth ground
(less than 1 ohm)

G

Accessories

3-Pin Mini-Style Cordsets

Model

Length

Style

Dimensions

Pinout

MBCC-306

2 m (6.5 ft)

Straight

7/8-16UN-2B

ø 2.5 mm

typ.

52 mm

typ.

2

3

1

1 = Black
2 = Brown
3 = Blue

MBCC-312

4 m (12 ft)

MBCC-330

9 m (30 ft)

VALU-BEAM SMI912 Series

8

www.bannerengineering.com - tel: 763-544-3164

P/N 03396 Rev. K

Advertising