Banner S18 Series User Manual

S18 sensors – dc-voltage series, Installation guide, Warning

Advertising
background image

Printed in USA

10/04

P/N 116159

Installation

Guide

S18 Sensors – dc-Voltage Series

Self-contained, dc-operated sensors

WARNING . . .

Not To Be Used for Personnel Protection

Never use these products as sensing devices for personnel protection.

Doing so could lead to serious injury or death. These sensors do

NOT include the self-checking redundant circuitry necessary to allow their use in

personnel safety applications. A sensor failure or malfunction can cause either

an energized or de-energized sensor output condition. Consult your current

Banner Safety Products catalog for safety products which meet OSHA, ANSI and

IEC standards for personnel protection.

!

Additional information on this product is immediately available online at

www.bannerengineering.com/116159

View or download additional information, including excess gain curves, beam patterns and accessories.

For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.

* Standard 2 m (6.5') cable models are listed.

9 m (30') cable: add suffix “W/30” (e.g., S186E W/30).

4-pin Euro-style QD models: add suffix “Q” (e.g., S186EQ). A model with a QD connector requires a

mating cable.

† Use polarized models when shiny objects will be sensed.

Sensing Mode

Range

LED

Output

Model*

Opposed

20 m

(66')

Infrared

950 nm

S186E

NPN

S18SN6R

PNP

S18SP6R

Retro-

reflective

2 m

(79")

NPN

S18SN6L

PNP

S18SP6L

Polarized

Retro-

reflective

Visible

Red

680 nm

NPN

S18SN6LP

PNP

S18SP6LP

Diffuse

100 mm

(4")

Infrared

880 nm

NPN

S18SN6D

PNP

S18SP6D

300 mm

(12")

NPN

S18SN6DL

PNP

S18SP6DL

Fixed

Field

25 mm (1")

cutoff

NPN

S18SN6FF25

PNP

S18SP6FF25

50 mm (2")

cutoff

NPN

S18SN6FF50

PNP

S18SP6FF50

100 mm (4")

cutoff

NPN

S18SN6FF100

PNP

S18SP6FF100

Dimensions

78.0 mm*

(3.07")

37.0 mm

(1.46")

Yellow LED

Output Indicator

Jam Nuts

(2 Provided)

18 x 1 mm

Thread

Green LED

Power Indicator

*Polarized retro and fixed-field models = 83.8 mm (3.30")

Cabled Models

QD Models

59.2 mm*

(2.33")

Yellow LED

Output Indicator

37.0 mm

(1.46")

Jam Nuts

(2 Provided)

18 x 1 mm

Thread

2 m

(6.5') Cable

Green LED

Power Indicator

*Polarized retro and fixed-field models = 65.0 mm (2.56")

P

LISTED

R

bn

bu

wh

bk

+

10 - 30V dc

Load
Load

Cabled Emitters

bu

bn

wh

bk

10 - 30V dc

Load

Alarm

+

bn

bu

10-30V dc

+

NPN (Sinking) Outputs

Standard Hookup

10 - 30V dc

No Connection

bu

bk

bn

wh

+

PNP (Sourcing) Outputs

Standard Hookup

QD Emitters

Alarm Hookup

Alarm Hookup

bu

bn

wh

bk

+

10 - 30V dc

Load
Load

bn

bu

wh

bk

10 - 30V dc

Load

Alarm

+

NOTE: QD hookups are functionally identical.

Advertising