S18 sensors – dc-voltage series, Specifications quick-disconnect (qd) cables – Banner S18 Series User Manual

Page 2

Advertising
background image

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: [email protected]

S18 Sensors – dc-Voltage Series

WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for

one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its

manufacture found to be defective at the time it is returned to the factory during the warranty

period. This warranty does not cover damage or liability for the improper application of

Banner products. This warranty is in lieu of any other warranty either expressed or implied.

P/N 116159

Supply Voltage and Current (exclusive of load current): 10 to 30V dc (10% max.

ripple); supply current (exclusive of load current):

Emitters, Non-Polarized Retro, Diffuse: 25 mA

Receivers: 20 mA

Polarized Retroreflective: 30 mA

Fixed-Field: 35 mA

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current

sourcing) models

Light Operate: N.O. output conducts when sensor sees its own (or the

emitter’s) modulated light

Dark Operate: N.C. output conducts when the sensor sees dark; the N.C.

(normally closed) output may be wired as a normally open

marginal signal alarm output, depending upon hookup to power

supply (U.S. patent 5087838)

Output Rating
150 mA maximum (each) in standard hookup. When wired for alarm output, the

total load may not exceed 150 mA.

OFF-state leakage current: < 1 microamp @ 30V dc

ON-state saturation voltage: < 1V at 10 mA dc; < 1.5V at 150 mA dc

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or short

circuit of outputs

Output Response Time

Opposed mode: 3 ms ON, 1.5 ms OFF

Retro, Fixed-Field and Diffuse: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this time.

Repeatability
Opposed mode: 375 µs
Retro, Fixed-Field and Diffuse:
750 µs

Repeatability and response are independent of signal strength.

Indicators

Two LEDs (Green and Yellow)

Green ON steady:

power to sensor is ON

Green flashing: output is overloaded

Yellow ON steady: N.O. output is conducting

Yellow flashing: excess gain marginal (1 to 1.5x) in light condition

Construction

PBT polyester housing; polycarbonate (opposed mode) or acrylic lens

Environmental Rating

Leakproof design rated NEMA 6P, DIN 40050 (IP69K)

Connections

2 m (6.5') or 9 m (30') attached cable, or 4-pin Euro-style quick-disconnect

fitting

Operating Conditions
Temperature:
-40° to +70°C (-40° to +158°F)

Maximum relative humidity: 90% at 50°C (non-condensing)
Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration;

frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration 10G).

Method 213B conditions H&I (Shock: 75G with unit operating; 100G for

non-operation)

Certifications

LISTED

R

Specifications

Quick-Disconnect (QD) Cables

Additional information on this product is immediately available online at

www.bannerengineering.com/116159

View or download additional information, including excess gain curves, beam patterns and accessories.

For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.

Style

Model

Length

Dimensions

Pin-Out

4-pin

Euro-style

Straight

MQDC-406

MQDC-415

MQDC-430

2 m (6.5')

5 m (15')

9 m (30')

4-pin

Euro-style

Right-angle

MQDC-406RA

MQDC-415RA

MQDC-430RA

2 m (6.5')

5 m (15')

9 m (30')

38 mm max.

(1.5")

M12 x 1

ø 15 mm

(0.6")

38 mm max.

(1.5")

M12 x 1

ø 15 mm

(0.6")

44 mm max.

(1.7")

White Wire

Brown Wire

Black Wire

Blue Wire

Advertising