L-gage q50a, Analog output sensor, L-gage q50a hookups – Banner L-GAGE Q50 Series—Analog User Manual

Page 7: Cable models quick-disconnect models

Advertising
background image

L-GAGE Q50A Analog Output Sensor Specifications (continued)

L-GAGE Q50A Dimensions

L-GAGE Q50A –

Analog Output Sensor

page

7

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

19.7 mm

(0.77")

60.0 mm

(2.36")

4.0 mm

(0.16")

4.0 mm

(0.16")

41.8 mm

(1.65")

52.0 mm

(2.05")

77.0 mm

(3.03")

49.8 mm

(1.96")

67.3 mm

(2.65")

2x ø3.4 mm
(0.13")

25 mm
(0.98")

15 mm
(0.59")

M3 Hardware is Included

15 mm
(0.59")

RANGE

IN

OUT

TEACH

OUTPUT

bn

bu

bn

bu

gy

bk response

Teach

wh

15-30V dc

5-30V dc
4ms

+5-30V dc

Bare

0-2V dc
64ms

+

Load

L-GAGE™

Q50AUQ

RANGE: 100 - 400m

m

bn

bu

bn

bu

gy

bk

response

Teach

wh

15-30V dc

5-30V dc
4ms

+5-30V dc

Bare

0-2V dc
64ms

+

Load

L-GAGE™

Q50AU

RANGE: 100 - 400m

m

To Set NEAR and FAR Limits.

1. Press and hold Teach button until the

Teach light turns on (RED)

2. Adjust target to 1st limit position.

Press Teach button. (Teach flashes)

3. Adjust target to 2nd limit position.

Press Teach button (Teach turns off)

Emitter

Receiver

bn

bu

bn

bu

gy

bk Response

Teach

wh

15-30V dc

5-30V dc
4ms

+5-30V dc

Bare

0-2V dc
64ms

+

Load

15-30V dc

+

bn

bu

gy

bk

Response

Teach

wh

+5-30V dc

Bare

Load

5-30V dc
4ms

0-2V dc
64ms

Connections

2 m or 9 m 5-conductor PVC-covered attached cable or 5-pin Euro-style quick disconnect

Construction

Housing: Molded ABS/Polycarbonate
Window Lens: Acrylic

Environmental Rating

IEC IP67, NEMA 6

Vibration and
Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max. double amplitude
0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 ms duration, half sine
wave.

Operating Conditions

Temperature:

-10° to +55°C (+14° to +131°F)

Max. Rel. Humidity: 90% at +50°C (non-condensing)

Application Notes

Allow 15-minute warm-up for maximum linearity.

Hardware

M3 hardware is included.

L-GAGE Q50A Hookups

Cable Models

Quick-Disconnect Models

Advertising
This manual is related to the following products: