Banner Q45 Laser DC Series User Manual

45lm series modules, Features, Specifications

Advertising
background image

Printed in USA

07/04

P/N 63416 rev. A

45LM Series Modules

Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

Features

• Three plug-in modules are available:

• Models with selectable output timing offer the following timing logic functions (see

page 2 or 3 for descriptions):

- ON-delay

- ON-delayed one-shot

- OFF-delay

- Repeat cycle timer

- ON- and OFF-delay

- Limit timer

- Retriggerable one-shot

- Rate sensor

- Non-retriggerable one-shot

- Flip-flop (alternate action)

- Delayed one-shot

• Selectable timing ranges:

0.01 to 0.15 seconds

0.1 to 1.5 seconds

1 to 15 seconds

• Delay and hold time ranges may be individually selected, and times precisely set,

using 15-turn adjustment potentiometers. Delay or hold time may also be disabled

(zero seconds).

• Module allows sensor output to be set for normally-open or normally-closed

operation

• Models with signal strength display give a precise indication of excess gain; see

page 4 for more information. Valuable for sensor setup and alignment, for critical

evaluation of alternative sensing schemes, and for close monitoring of sensing

performance over time (e. g., dirt build-up on lenses or progressive misalignment).

Model

Functions

45LM58

Selectable output timing

45LM58D

Selectable output timing, plus signal strength display

45LMD

Signal strength display, only (no programmable functions)

Specifications

Operating Temperature

-40° to +70°C (-40° to +158°F)

Timing Adjustments

Models 45LM58.. only: Two 15-turn clutched potentiometers with brass elements, accessible from

outside at the top of sensor, beneath an o-ring sealed polycarbonate cover.

Timing Repeatability

Models 45LM58.. only: Plus or minus 2% of the timing range (maximum); assumes conditions of

constant temperature and power supply.

Useful Time Range

Models 45LM58.. only: Useful time range is from maximum time down to 5% of maximum. When the

timing potentiometer is set fully counterclockwise, time will be approximately 5%

of maximum.

Response Time

Models 45LM58.. only: When the delay time is switched OFF, the card adds no measurable sensing

response time.

LED Display

Models 45LM..D only: Seven-element LED display, visible through transparent top sensor cover. The

more LEDs that are lit, the stronger is the received light signal; three LEDs lit is

equivalent to an excess gain of about 1x (see page 4).