45lm series modules – Banner Q45 Laser DC Series User Manual

Page 3

Advertising
background image

P/N 63416 rev. A

3

45LM Series Modules

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Selecting ON-Delay Time Range

Switch 4

Switch 5

Delay

(min. to max.)

OFF

OFF

OFF – no delay

OFF

ON

0.01 to 0.15 sec.

ON

OFF

0.1 to 1.5 sec.

ON

ON

1 to 15 sec.

Selecting Hold Time (OFF-Delay) Range

Switch 6

Switch 7

Hold

(min. to max.)

OFF

OFF

OFF – no hold

OFF

ON

0.01 to 0.15 sec.

ON

OFF

0.1 to 1.5 sec.

ON

ON

1 to 15 sec.

Selecting Output State

Switch 8

Output State

Rate Sensor Logic

ON

Output de-energizes above the set rate

OFF

Output energizes above the set rate

Flip-Flop Logic

ON

Output changes state at trailing edge of signals

OFF

Output changes state at leading edge of signals

All Other Logic

ON

Normally closed: output de-energizes during Hold time

OFF

Normally open: output energizes during Hold time

Output Timing Function: ON-delayed one-shot

Switch 1

Switch 2

Switch 3

Other Settings

OFF

ON

OFF

Output

Signal

Hold

Delay

Output Timing Function: Repeat cycle timer

Switch 1

Switch 2

Switch 3

Other Settings

OFF

OFF

ON

Output

Signal

Hold

Delay

Hold

Delay

Output Timing Function: Limit timer

Switch 1

Switch 2

Switch 3

Other Settings

ON

OFF

ON

Output

Signal

Hold

Output Timing Function: Rate sensor

Switch 1

Switch 2

Switch 3

Other Settings

OFF

ON

ON

Output

< Hold

Signal

> Hold

Output Function: Flip-flop

Switch 1

Switch 2

Switch 3

Other Settings

ON

ON

ON

Output

Signal

p/n 63416 Rev. B