L-gage q50a, Complementary discrete output sensor, L-gage q50a hookups – Banner L-GAGE Q50 Series User Manual

Page 7

Advertising
background image

L-GAGE Q50A Complementary Discrete Output Sensor Specifications (continued)

L-GAGE Q50A Dimensions

L-GAGE Q50A –

Complementary Discrete Output Sensor

page

7

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

19.7 mm

(0.77")

60.0 mm

(2.36")

4.0 mm

(0.16")

4.0 mm

(0.16")

41.8 mm

(1.65")

52.0 mm

(2.05")

77.0 mm

(3.03")

49.8 mm

(1.96")

67.3 mm

(2.65")

2x ø3.4 mm
(0.13")

25 mm
(0.98")

15 mm
(0.59")

15 mm
(0.59")

RANGE

IN

OUT

TEACH

OUTPUT

s

To Set NEAR and FAR Limits.

1. Press and hold Teach button until the

Teach light turns on (RED)

2. Adjust target to 1st limit position.

Press Teach button. (Teach flashes)

3. Adjust target to 2nd limit position.

Press Teach button (Teach turns off)

Emitter

Receiver

Q50AVNQ

+

L-GAGE™

RANGE: 100 - 400 mm

Load

bu

12-30V dc

Output 2

Output 1

Teach

+5-30V dc

bn

bk

wh

gy

Load

Q50AVN

+

L-GAGE™

RANGE: 100 - 400 mm

Load

bu

12-30V dc

Output 2

Output 1

+5-30V dc

Bare

bn

bk

wh

gy

Load

+

Load

bu

12-30V dc

Output 2

Output 1

+5-30V dc

Bare

bn

bk

wh

gy

Load

+

Load

bu

12-30V dc

Output 2

Output 1

Teach

+5-30V dc

bn

bk

wh

gy

Load

+

Load

bn

12-30V dc

Output 2

Output 1

+5-30V dc

Bare

bu

bk

wh

gy

Load

+

Load

bn

12-30V dc

Output 2

Output 1

Teach

+5-30V dc

bu

bk

wh

gy

Load

Connections

2 m or 9 m 5-conductor PVC-covered attached cable or 5-pin Euro-style quick disconnect

Construction

Housing: Molded ABS/Polycarbonate
Window Lens: Acrylic

Environmental Rating

IEC IP67, NEMA 6

Vibration and
Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max. double amplitude
0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 ms duration, half sine
wave.

Operating Conditions

Temperature:

-10° to +55°C (+14° to +131°F)

Max. Rel. Humidity: 90% at +50°C (non-condensing)

Application Notes

Allow 15-minute warm-up for maximum performance.

Hardware

M3 hardware is included.

L-GAGE Q50A Hookups

NPN Hookups

Cabled Models

Quick-Disconnect Models

PNP Hookups

Cabled Models

Quick-Disconnect Models

Advertising