Plastic Fiber Optic Models

Lower in cost than glass fiber optics, plastic fiber optics are ideal for use in situations where environmental

conditions allow (for example, low levels of acids, alkalis, and solvents). Most are easily cut to length in the

field, and are available in a variety of sensing end styles. For more information on compatible plastic fiber

optics, refer to your current catalog.

Diffuse mode performance curves are based on a 90% reflectance white test card.

Range: Range varies by sensing mode and fiber optics used.

Output Type: SPDT Electro-mechanical relay

PLASTIC FIBER

Visible red, 660 nm

Models

Cable

Excess Gain

Beam Pattern

Q45VR2FP

5-wire 2 m (6.5 ft) cable

1

10

100

10 mm

0.4 in

100 mm

4.0 in

1000 mm

40 in

1 mm

0.04 in

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

Q45FP

Opposed Mode

PIT46U Fibers

PIT26U Fibers

1

10

100

1 mm

0.04 in

10 mm

0.4 in

100 mm

4 in

0.1 mm

0.004 in

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

Q45FP

Diffuse Mode

PBT46U Fiber

PBT26U Fiber

125 mm

5.0 in

100 mm

4.0 in

75 mm

3.0 in

50 mm

2.0 in

25 mm

1.0 in

0

0

15 mm

30 mm

45 mm

15 mm

30 mm

45 mm

0

0.6 in

1.2 in

1.8 in

0.6 in

1.2 in

1.8 in

DISTANCE

Q45FP

Opposed Mode

PIT46U Fibers

PIT26U Fibers

50 mm

2.0 in

40 mm

1.6 in

30 mm

1.2 in

20 mm

0.8 in

10 mm

0.4 in

0

0

6 mm

12 mm

18 mm

6 mm

12 mm

18 mm

0

0.25 in

0.50 in

0.75 in

0.25 in

0.50 in

0.75 in

DISTANCE

Q45FP

Diffuse Mode

PBT46U Fiber

Q45VR2FPQ

5-Pin Mini-style QD

To order the 9 m (30 ft) cable model, add suffix "W/30" to the cabled model number. (For example: Q45VR2FP W/30.)

Models with a QD connector require a mating cable.

Overview

Status indicator LEDs for power, signal, and output are clearly visible beneath a raised dome in the sensor’s transparent o-

ring-sealed polycarbonate cover. Also located beneath the sensor’s o-ring-sealed cover are controls for light/dark operate

selection and the sensitivity adjustment.

The power indicator (green) lights when power is applied to the sensor.

The signal indicator (red) lights when the sensor sees its modulated light source and pulses at a rate proportional

to the strength of the received light signal; this is the AID

Alignment Indicating Device

2

.

The output indicator (amber) lights when the sensor’s output is conducting. This indicator is especially useful when

a timing logic module is used and signal and output conditions are not concurrent.

1

3

4

5

6

2

1. Sensitivity adjustment
2. LEDs

Green LED: Power on indicator

Red LED: Signal indicator

Amber LED: Output status indicator

3. Optional LED signal strength display
4. Optional timing adjustment
5. Optional timing adjustment
6. Light/dark operate switch

2 US patent no. 4356393

Q45VR2 Series Sensors

6

www.bannerengineering.com - tel: 763-544-3164

P/N 36339 Rev. F