WARNING: Explosion Hazard
Do not disconnect equipment unless power has been switched Off or the area is known to be non-hazardous.

Specifications

Supply Voltage and Current

5 to 15V dc (provided by the amplifier to which the sensor is connected)

Output

Constant current output: ≤ 1.2 mA in the “dark” condition and ≥ 2.1 mA
in the “light” condition

Output Response Time

Opposed mode: 2 ms ON/400 μs OFF
All other modes: 5 ms ON/OFF (does not include amplifier response)

Adjustments

15-turn slotted brass screw GAIN (sensitivity) adjustment potentiometer
(clutched at both ends of travel); located on rear panel and protected by
a clear gasketed acrylic cover

Indicators

Red LED Alignment Indicator Device (AID) located on rear panel lights
when the sensor sees a “light” condition; pulse rate is proportional to
signal strength (the stronger the signal, the faster the pulse rate).

Construction

Reinforced thermoplastic polyester housing, totally encapsulated, o-ring
sealing, acrylic lenses, and stainless steel screws

Environmental Rating

Banner tested to NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12 and 13
IEC IP67

Connections

PVC-jacketed 2-conductor 2 m or 9 m cables, or special 4-pin Euro-
style quick-disconnect (QD) fitting are available; QD cables are ordered
separately.

Operating Conditions

Temperature: −40 °C to +70 °C (−40 °F to +158 °F)

Design Standards
ATEX (European)

EN 60079-0, EN 60079-11, and EN 60079-26

Canadian

CAN/CSA C22.2, No. 142-M1987, No.157-92, No. 1010.1, E60079-0,
and E60079-11

United States

FM Class 3600, 3610, and 3810, ANSI/ISA 61010-1 (82.02.01),
ANSI/ISA 60079-0, 60079-11, and 60079-26

Approvals
ATEX (European)

II 1 G Ex ia IIC T5 Ga Ta = –40 °C to 70 °C - 39616; Entity;
FM12ATEX0094X
Entity Parameters:
V

Max

= 15 V dc, I

Max

= 60 mA, C

i

= 0.3 μF, L

i

= 0 mH.

Canada

Intrinsically safe for Class I, II and III, Division 1, Groups A, B, C, D, E, F
and G T5 Ta = –40 °C to 70 °C - 39616; Entity
Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = –40
°C to 70 °C
Intrinsically safe for Class I, Zone 0 Ex ia Group IIC T5 Ta = -40°C to
70°C - 39616; Entity
Entity Parameters:
V

Max

= 15 V dc, I

Max

= 60 mA, C

i

= 0.3 μF, L

i

= 0 mH.

a = Sensing mode D, W, F, LV, LVAG, CV, CV2 or R.
b = Connection method Q or blank.

United States

Intrinsically safe for Class I, II and III, Division 1, Groups A, B, C, D, E, F
and G T5 Ta = –40 °C to 70 °C - 39616; Entity
Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = –40
°C to 70 °C
Suitable for Class II and III, Division 2 (Class II and III, Division 2 applies
only to model numbers ending in suffix "Q"), Groups F and G*, T5 Ta = –
40 °C to 70 °C
Intrinsically safe for Class I, Zone 0 AEx ia Group IIC T5 Ga Ta = –40 °C
to 70 °C; Entity
Entity Parameters:
V

Max

= 15 V dc, I

Max

= 60 mA, C

i

= 0.3 μF, L

i

= 0 mH.

a = Sensing mode D, W, F, LV, LVAG, CV, CV2 or R.
b = Connection method Q or blank.

Certifications

MINI-BEAM® MIAD9 Series

P/N 39616_web Rev. I

www.bannerengineering.com - tel: 763-544-3164

3

Advertising
This manual is related to the following products: