Wiring, Accessories – Banner U-GAGE QT50U Ultrasonic Sensors User Manual

Page 9

Advertising
background image

Wiring

Cabled Models

QD Models

Normally Open/Pump-In

Normally Open/Pump-In

Load

bk

ye

bn
bu
wh

85-264V ac, 50/60 Hz

48-250V dc**

shield*

Output Current

8A Max.

bk

ye

bn
bu
wh

shield*

Output Current

(4A or 8A Max.)***

Load

85-264V ac, 50/60 Hz

48-250V dc**

Normally Closed/Pump-In

Normally Closed/Pump-In

bk

ye

bn
bu
wh

shield*

Output Current

8A Max.

Load

85-264V ac, 50/60 Hz

48-250V dc**

bk

ye

bn
bu
wh

shield*

Load

Output Current

(4A or 8A Max.)***

85-264V ac, 50/60 Hz

48-250V dc**

* Banner recommends that the shield wire be connected to earth ground.

** DC wiring is without regard to polarity

*** 4 A max. for sensors with Micro-style QD; 8 A max. for sensors with Mini-style QD.

Accessories

5-Pin Mini-Style Cordsets with Shield

Model

Length

Style

Dimensions

Pinout (Female)

MBCC2-506

1.83 m (6 ft)

Straight

7/8-16UN-2B

ø 28 mm max.

(1.1")

61 mm max.

(2.4")

4

3

1

5

2

1 = Brown

2 = White

3 = Blue

4 = Black

5 = Yellow

MBCC2-515

4.57 m (15 ft)

MBCC2-530

9.14 m (30 ft)

U-GAGE QT50UVR Series Sensors

P/N 117764 Rev. F

www.bannerengineering.com - tel: 763-544-3164